Chlorine dispenser pump failed. Will need to manually add chlorine until pump is replaced.
Cleaned ORP and PH probes
24 oz of TriChlor
8 gal of Liquid Chlorine • 12.5%
Added 8 gallons of 12.5% chlorinating liquid to feeder.
1 gal of 31.45% (20º Be) Muriatic Acid
Added 1 gallon muriatic acid and 3 gallons water to acid dispenser
$46.53 on Liquid Chlorine / Bleach • 12.5%
4 gallons in chlorine dispenser
$28.13 on Calcium increaser
8 lbs of Calcium Chloride
4 lbs of Baking Soda
2.0
FC
2.0
CC
7.7
pH
45
TA
252
CH
20
CYA
87 °F
TEMP
-0.21
CSI
10 gallons in chlorine dispenser
3.8
FC
3.9
CC
7.7
pH
53
TA
292
CH
19
CYA
90 °F
TEMP
-0.04
CSI
13 gallons of chlorine in dispenser
3.8
FC
3.8
CC
7.7
pH
56
TA
271
CH
21
CYA
90 °F
TEMP
-0.05
CSI
16 oz of TriChlor
1.7
FC
1.7
CC
7.7
pH
66
TA
276
CH
8
CYA
89 °F
TEMP
0.06
CSI
12 gal of Liquid Chlorine • 10%
Added 12 gallons of 10% chlorinating liquid to feeder.
Feeder still had ~2 gallons
3.0
FC
3.0
CC
7.7
pH
59
TA
272
CH
15
CYA
89 °F
TEMP
-0.02
CSI
$51.90 on Liquid Chlorine / Bleach • 10%
ORP 705mV = 2.50 FC
Cleaned ORP and PH probes
Backwashed
Filter Pressure:
22
3oz Orenda PR-10,000
3.0
FC
3.0
CC
7.7
pH
66
TA
285
CH
18
CYA
88 °F
TEMP
0.05
CSI
8 oz of TriChlor
2 lbs of Baking Soda
3.3
FC
3.3
CC
7.7
pH
60
TA
290
CH
20
CYA
85 °F
TEMP
-0.03
CSI
12 gal of Liquid Chlorine • 10%
Added 12 gallons of 10% chlorinating liquid to feeder.
Feeder still had ~1 gallon
$51.90 on Liquid Chlorine / Bleach • 10%
$18.38 on Other • Skimmer Socks
3.4
FC
3.4
CC
7.7
pH
60
TA
299
CH
20
CYA
86 °F
TEMP
0.00
CSI
ORP 700mV = 2.74 FC
2.8
FC
2.8
CC
7.7
pH
60
TA
280
CH
18
CYA
87 °F
TEMP
-0.02
CSI
8 oz of TriChlor
$50.87 on Trichlor tablets/pucks
2.3
FC
2.3
CC
7.7
pH
60
TA
272
CH
15
CYA
87 °F
TEMP
-0.02
CSI
2 lbs of Baking Soda
3 gal of 31.45% (20º Be) Muriatic Acid
Added 3 gallon muriatic acid and 9 gallons water to acid dispenser
ORP setpoint changed to 715mV
Added 40oz 10% bleach manually. Part of the 12 gallons added to feeder
The addition of Calcium chloride has impacted ORP readings by +80-100 mV. Until stable will be adding liquid chlorine manually.
Added 12 gallons of 10% chlorinating liquid to feeder.
Feeder still had 3 gallons.
8 lbs of Calcium Chloride
2.0
FC
2.0
CC
7.7
pH
45
TA
230
CH
20
CYA
86 °F
TEMP
-0.25
CSI
$28.10 on Muriatic acid
12 gal of Liquid Chlorine • 10%
$51.90 on Liquid Chlorine / Bleach • 10%
Replaced CAX-3512 3X7 SANTOPRENE FEED TUBE-31.68GPD on both Acid and Chlorine Pumps.
Replaced CAX-3504 - PVC Blue Suction tube on both Acid and Chlorine pumps
Purchased parts from Sunplay
Cleaned ORP and PH probes
1.8
FC
1.8
CC
7.7
pH
60
TA
290
CH
20
CYA
83 °F
TEMP
-0.04
CSI
$28.13 on Calcium increaser
Backwashed
Filter Pressure:
22
3oz Orenda PR-10,000
$27.42 on Other • Orenda PR-10,000
4 lbs of Baking Soda
3.1
FC
3.1
CC
7.7
pH
50
TA
280
CH
20
CYA
72 °F
TEMP
-0.24
CSI
ORP setpoint changed to 710mV
3.1
FC
3.1
CC
7.7
pH
60
TA
320
CH
20
CYA
78 °F
TEMP
-0.05
CSI
ORP set point changed to 715mV
12 gal of Liquid Chlorine • 10%
Added 12 gallons of 10% chlorinating liquid to feeder.
ORP set point changed to 720mV
$51.90 on Liquid Chlorine / Bleach • 10%
ORP 670mV = 1.50 FC
3.1
FC
3.1
CC
7.7
pH
60
TA
330
CH
20
CYA
71 °F
TEMP
-0.10
CSI
Filter Pump repaired. Loose wire secured inside Omni panel.
Filter Pump stopped working. Added 30oz manually
3.5
FC
3.5
CC
7.7
pH
60
TA
320
CH
25
CYA
68 °F
TEMP
-0.14
CSI
3.8
FC
3.8
CC
7.7
pH
65
TA
330
CH
25
CYA
70 °F
TEMP
-0.07
CSI
ORP set-point changed to 725mV
1 gal of 31.45% (20º Be) Muriatic Acid
Added 1 gallon muriatic acid and 3 gallons water to acid feeder
$7.00 on Muriatic acid
2.5
FC
2.5
CC
7.7
pH
70
TA
340
CH
25
CYA
70 °F
TEMP
-0.03
CSI
Change ORP set-point from 715mV to 730mV to accommodate change in ORP due to Ozonator
Added Ozonator back to schedule. Runs from 10am - 8pm
Cleaned ORP and PH probes
2.3
FC
7.7
pH
70
TA
350
CH
25
CYA
68 °F
TEMP
-0.03
CSI
3.7
FC
3.7
CC
7.7
pH
80
TA
340
CH
30
CYA
72 °F
TEMP
0.04
CSI
Changed PH set-point for 7.8 to 7.7
3.1
FC
3.1
CC
7.8
pH
80
TA
330
CH
30
CYA
61 °F
TEMP
0.03
CSI
Changed ORP set-point to 715mV
FC range ~2-4ppm
Set ORP to 700mV. Auto dispense bleach based on 700mV
Results:
ORP = 700
FC = 3.52
2.4
FC
2.4
CC
7.9
pH
78
TA
320
CH
31
CYA
53 °F
TEMP
0.02
CSI
Backwashed
Filter Pressure:
22
Ozonator rewired to support Independent control. Turned off while pool pump running. Only runs in spa mode
2.2
FC
2.2
CC
7.7
pH
85
TA
339
CH
34
CYA
53 °F
TEMP
-0.12
CSI
Stenner pump dispense rates
10% Liquid Chlorine @ .047 oz per second
Muriatic Acid 3:1 dilution @ .012 oz per second
Test performed with ExactiDip photometer and checked against Taylor Drop test and Lamotte Spintouch
2.4
FC
2.5
CC
7.7
pH
80
TA
330
CH
30
CYA
58 °F
TEMP
-0.10
CSI
ORP = 745
4.7
FC
4.7
CC
7.7
pH
81
TA
295
CH
33
CYA
55 °F
TEMP
-0.18
CSI
20 oz of Liquid Chlorine • 10%
$32.46 on Diatomaceous Earth
BackwashedCleaned Filter
Filter Pressure:
22
2.0
FC
2.3
CC
7.6
pH
78
TA
373
CH
39
CYA
54 °F
TEMP
-0.22
CSI
ORP set to 720mV and dispensing chlorine automatically
ORP = 750
Using Borates field to track ORP
2.8
FC
2.8
CC
7.6
pH
76
TA
356
CH
35
CYA
50 °F
TEMP
-0.27
CSI
PH is monitored and dispensed automatically. Set to 7.7
ORP is monitored. Still adding Chlorine manually.
3.5 gal of 31.45% (20º Be) Muriatic Acid
12 gal of Liquid Chlorine • 10%
Filled Acid dispenser with 11 gallons water, 3 1/2 gallons muriatic acid.
Filled Chlorine dispenser with 12 gallons of 10% Liquid Chlorine.