Montgomery Pool

Volume: 23500 Gallons
Build Type: Fiberglass
Left filter on rinse and lost water to about half the diamond. Had to add water!
Vacuumed Backwashed Brushed Cleaned Filter
Filter Pressure:10
128 oz of Liquid Chlorine • 12.5%
1.5
FC
0.5
CC
7.6
pH
130
TA
400
CH
50
CYA
0
BOR
75 °F
TEMP
Vacuumed Backwashed Brushed
Filter Pressure:10
90 oz of Borax (20 Mule)
5.0
FC
0.5
CC
0.5
FC
0.5
CC
110
TA
500
CH
45
CYA
72 °F
TEMP
609 oz of Calcium Chloride
128 oz of Liquid Stabilizer
35 lbs of Calcium Chloride
5.0
FC
175
CH
25
CYA
70 °F
TEMP
Cleaned Filter
Opened Pool Vacuumed Backwashed Brushed
Filter Pressure:10
10.0
FC
2.0
CC
7.2
pH
60
TA
100
CH
10
CYA
65 °F
TEMP
$39.99 on Polyquat (algaecide)
$15.88 on Dichlor powder
$39.99 on Alkalinity increaser (baking soda)
9.0
FC
0.0
CC
60 oz of Liquid Chlorine • 12.5%
Vacuumed Backwashed Cleaned Filter
For some reason the pool is green today. The numbers were alright and I manually vacuumed yesterday, so I’m not sure what caused this. Backwashes, cleaned filter and added a gallon of liquid chlorine. We’ll see?
128 oz of Liquid Chlorine • 12.5%
Vacuumed Backwashed Brushed Cleaned Filter
Filter Pressure:20
3 lbs of Dry Stabilizer
12 oz of Borax (20 Mule)
24 oz of Liquid Chlorine • 12.5%
4.0
FC
0.0
CC
7.5
pH
60
TA
275
CH
20
CYA
79 °F
TEMP
48 oz of Liquid Chlorine • 12.5%
3.5
FC
0.0
CC
3 lbs of Dry Stabilizer
60 oz of Liquid Chlorine • 12.5%
48 oz of Borax (20 Mule)
2.5
FC
0.0
CC
7.2
pH
40
TA
275
CH
0
CYA
78 °F
TEMP
48 oz of Liquid Chlorine • 12.5%
4.0
FC
0.0
CC
5.5
FC
0.0
CC
7.2
pH
60
TA
275
CH
10
CYA
80 °F
TEMP
3.5
FC
0.5
CC
Pool Store Test Results: FC 3.97 CC 0 TC 3.97 4.5 PH 7.9 7.5 CH 137 200 TA 52 60 CYA 36 -10
Vacuumed Backwashed Brushed Cleaned Filter
Filter Pressure:21
25 lbs of Calcium Chloride
1 gal of Liquid Chlorine • 12.5%
64 oz of Liquid Stabilizer
4.5
FC
0.0
CC
7.5
pH
60
TA
200
CH
36
CYA
7.5
pH
Vacuumed Backwashed Brushed Cleaned Filter
2.0
FC
0.0
CC
128 oz of Liquid Chlorine • 12.5%
4.5
FC
0.5
CC
132 oz of Liquid Chlorine • 12.5%
40 oz of Liquid Chlorine • 12.5%
7.5
FC
0.5
CC
7.5
pH
60
TA
200
CH
20
CYA
82 °F
TEMP
48 oz of Liquid Chlorine • 12.5%
8.0
FC
0.5
CC
Vacuumed Backwashed Brushed Cleaned Filter
Filter Pressure:21
10.0
FC
0.5
CC
7.5
pH
60
TA
225
CH
25
CYA
84 °F
TEMP
10.5
FC
0.5
CC
25
CYA
15.5
FC
0.5
CC
48 oz of Liquid Chlorine • 12.5%
9.0
FC
1.0
CC
7.5
pH
28
CYA
85 °F
TEMP
156 oz of Liquid Chlorine • 12.5%
4.5
FC
0.5
CC
7.5
pH
28
CYA
85 °F
TEMP
Pool is getting green. No maintenance because Tyson was here for 8 days.
Brushed
64 oz of Liquid Stabilizer
84 oz of Liquid Chlorine • 12.5%
30 oz of Borax (20 Mule)
1.5
FC
2.0
CC
7.4
pH
60
TA
225
CH
20
CYA
84 °F
TEMP
Backwashed Cleaned Filter
1.0
FC
0.0
CC
7.3
pH
60
TA
225
CH
28
CYA
80 °F
TEMP
60 oz of Liquid Chlorine • 12.5%
54 oz of Borax (20 Mule)
60 oz of Liquid Chlorine • 12.5%
Vacuumed Backwashed Brushed Cleaned Filter
Filter Pressure:22
8 lbs of Calcium Chloride
84 oz of Liquid Stabilizer
72 oz of Liquid Chlorine • 12.5%
2.0
FC
0.5
CC
7.2
pH
60
TA
250
CH
28
CYA
60 oz of Liquid Chlorine • 12.5%
2.5
FC
0.5
CC
7.5
pH
70
TA
275
CH
35
CYA
80 °F
TEMP
5 lbs of Calcium Chloride
62 oz of Borax (20 Mule)
28 oz of Liquid Stabilizer
60 oz of Liquid Chlorine • 12.5%
2.5
FC
0.5
CC
7.2
pH
70
TA
250
CH
35
CYA
82 °F
TEMP
Stardust Pools came out and plugged the 2 extra returns. They also caulked the inside of the skimmer to try to stop pool from leaking.
Pool not leaking water! 🙏🏿
Vacuumed Backwashed Brushed Cleaned Filter
Filter Pressure:22
163 oz of Liquid Stabilizer
12 oz of Liquid Chlorine • 12.5%
3.5
FC
0.5
CC
7.5
pH
70
TA
350
CH
20
CYA
78 °F
TEMP
60 oz of Liquid Chlorine • 12.5%
4.0
FC
0.5
CC
7.4
pH
70
TA
350
CH
27
CYA
79 °F
TEMP
Vacuumed
Filter Pressure:22
60 oz of Liquid Chlorine • 12.5%
4.0
FC
1.0
CC
7.3
pH
100
TA
375
CH
30
CYA
70 °F
TEMP
106 oz of Liquid Stabilizer
18 oz of Borax (20 Mule)
87 oz of Calcium Chloride
5.0
FC
1.0
CC
7.5
pH
90
TA
325
CH
27
CYA
75 °F
TEMP
60 oz of Borax (20 Mule)
60 oz of Liquid Chlorine • 12.5%
2.5
FC
2.0
CC
7.2
pH
70
TA
350
CH
35
CYA
70 °F
TEMP
348 oz of Calcium Chloride
1 gal of Liquid Stabilizer
8.0
FC
1.0
CC
7.5
pH
90
TA
250
CH
10
CYA
70 °F
TEMP
Vacuumed Brushed
Filter Pressure:22
Return pipes from filter blew off. Needed to change pipes and pressure valve.
400 oz of Calcium Chloride
24 oz of Liquid Chlorine • 12.5%
Vacuumed Backwashed Cleaned Filter
Filter Pressure:20
5.6
FC
0.0
CC
7.5
pH
102
TA
92
CH
38
CYA
70 °F
TEMP
60 oz of Liquid Chlorine • 12.5%
2.5
FC
0.5
CC
7.2
pH
90
TA
200
CH
35
CYA
70 °F
TEMP
3.0
FC
5.0
CC
7.5
pH
110
TA
175
CH
17
CYA
70 °F
TEMP
0.3
FC
0.2
CC
7.5
pH
110
TA
175
CH
0
CYA
70 °F
TEMP
Brushed
Vacuumed Backwashed Brushed
Filter Pressure:6