Changed pump from running at night to running during the day
27 °C
TEMP
0.49
CSI
Opened auto fill 10.551
Backwashed
400 mL of 31.45% (20º Be) Muriatic Acid
300 g of TriChlor
8.0
FC
7.8
pH
0.51
CSI
600 mL of 31.45% (20º Be) Muriatic Acid
2000 mL of Liquid Chlorine • 12%
2.0
FC
8.0
pH
0.71
CSI
12.0
FC
0.5
CC
7.8
pH
0.51
CSI
Replaced right skimmer door
Added 3 tabs in floater
3000 mL of Liquid Chlorine • 12%
2.0
FC
7.8
pH
0.51
CSI
Pumped off 4cm of water after lots of rain
Backwashed
1500 mL of Liquid Chlorine • 12%
3.0
FC
7.5
pH
0.22
CSI
6.0
FC
7.2
pH
-0.07
CSI
7.1
pH
28 °C
TEMP
-0.16
CSI
600 mL of 31.45% (20º Be) Muriatic Acid
9.0
FC
7.8
pH
0.46
CSI
750 mL of 31.45% (20º Be) Muriatic Acid
2500 mL of Liquid Chlorine • 12%
1.0
FC
8.3
pH
0.96
CSI
Backwashed
7.8
pH
0.46
CSI
350 mL of 31.45% (20º Be) Muriatic Acid
2000 mL of Liquid Chlorine • 12%
2.0
FC
8.5
pH
80
TA
700
CH
40
CYA
25 °C
TEMP
0.96
CSI
1000 mL of Liquid Chlorine • 12%
5.0
FC
7.4
pH
-0.08
CSI
12.5
FC
7.1
pH
21 °C
TEMP
-0.37
CSI
7.2
pH
-0.27
CSI
500 mL of 31.45% (20º Be) Muriatic Acid
16.0
FC
0.5
CC
8.2
pH
0.71
CSI
997 mL of 31.45% (20º Be) Muriatic Acid
4895 mL of Liquid Chlorine • 12%
3.0
FC
8.5
pH
20 °C
TEMP
1.00
CSI
Run robot
Run robot
Backwashed
1500 mL of Liquid Chlorine • 12%
4.0
FC
7.4
pH
12 °C
TEMP
-0.22
CSI
978 mL of 31.45% (20º Be) Muriatic Acid
5.0
FC
8.4
pH
0.73
CSI
RCD tripped. Pump last ran on Feb 9th
1440 mL of Liquid Chlorine • 12%
3.0
FC
7.4
pH
-0.25
CSI
Fuse had tripped n master panel
7.2
pH
-0.11
CSI
Pumped off 7-8cm of water
1000 mL of 31.45% (20º Be) Muriatic Acid
4.0
FC
8.2
pH
10 °C
TEMP
0.54
CSI
Run robot
Backwashed
Run robot
Backwashed
Run robot
1000 mL of 31.45% (20º Be) Muriatic Acid
1400 mL of Liquid Chlorine • 12%
6.0
FC
7.8
pH
0.47
CSI
Lubricated tracks for pool cover
Run robot
600 mL of 31.45% (20º Be) Muriatic Acid
8.0
FC
7.8
pH
0.47
CSI
Run robot
1100 mL of 31.45% (20º Be) Muriatic Acid
14.0
FC
8.2
pH
0.86
CSI
Backwashed
Pressure gauge broken
2000 mL of Liquid Chlorine • 12%
4607 mL of Liquid Chlorine • 12%
943 mL of 31.45% (20º Be) Muriatic Acid
$11.80 on Muriatic acid
4.0
FC
8.2
pH
0.86
CSI
$22.85 on Liquid Chlorine / Bleach • 12%
3000 mL of Liquid Chlorine • 12%
4.0
FC
8.0
pH
0.67
CSI
Run robot
600 mL of 31.45% (20º Be) Muriatic Acid
4895 mL of Liquid Chlorine • 12%
3.0
FC
7.8
pH
0.47
CSI
2000 mL of Liquid Chlorine • 12%
4.0
FC
7.4
pH
0.08
CSI
632 mL of 31.45% (20º Be) Muriatic Acid
1152 mL of Liquid Chlorine • 12%
6.0
FC
7.6
pH
0.27
CSI
Run robot
1440 mL of Liquid Chlorine • 12%
5.0
FC
7.4
pH
30 °C
TEMP
0.08
CSI
518 mL of 31.45% (20º Be) Muriatic Acid
1000 mL of Liquid Chlorine • 12%
7.0
FC
7.5
pH
0.19
CSI
1000 mL of Liquid Chlorine • 12%
7.0
FC
0.29
CSI
Run robot
Turned off auto fill 10.551
Opened auto fill 10.146
632 mL of 31.45% (20º Be) Muriatic Acid
12.0
FC
0.5
CC
7.6
pH
120
TA
50
CYA
31 °C
TEMP
0.29
CSI
Run robot
14.0
FC
-0.10
CSI
16.0
FC
0.5
CC
-0.10
CSI
Added trichlor tab in floater
Added a bit of DE to sand filter
Run pump 24x7
16.0
FC
-0.10
CSI
Added 1 tri chlor tab to floater
Closed auto fill 10.146
14.0
FC
0.5
CC
7.2
pH
-0.10
CSI
Opened auto fill 9.578
2 trichlor tabs I. Floater
Robot
600 mL of 31.45% (20º Be) Muriatic Acid
1300 mL of Liquid Chlorine • 12%
6.0
FC
7.5
pH
0.19
CSI
8.0
FC
7.5
pH
0.19
CSI
8.0
FC
7.5
pH
0.19
CSI
10.0
FC
7.2
pH
-0.10
CSI
Robot
Adde one tri chlor tab to floater
12.0
FC
-0.01
CSI
Run robot
8.0
FC
7.3
pH
-0.01
CSI
900 mL of Liquid Chlorine • 12%
6.0
FC
0.5
CC
7.1
pH
-0.20
CSI
500 mL of Liquid Chlorine • 12%
4.0
FC
7.2
pH
-0.10
CSI
Turned off auto fill 9.578
Opened auto fill 9.344
600 mL of 31.45% (20º Be) Muriatic Acid
1000 mL of Liquid Chlorine • 12%
3.0
FC
0.0
CC
7.5
pH
32 °C
TEMP
0.19
CSI
Turned off auto fill 9.344
Opened auto fill 8.560
Backwashed
SWG died
Added 3 trichlor tabs in floater
6.0
FC
0.5
CC
0.11
CSI
10.0
FC
0.5
CC
0.11
CSI
1100 mL of Liquid Chlorine • 12%
9.0
FC
0.5
CC
0.11
CSI
16.0
FC
0.5
CC
0.11
CSI
110
TA
30
CYA
5000
SALT
0.11
CSI
4463 mL of Liquid Chlorine • 12%
349 mL of 31.45% (20º Be) Muriatic Acid
0.5
FC
0.5
CC
7.4
pH
0.11
CSI
SWG reported lack of salt & pH 2.9
Configured to 60% fluctuating 3-11%
Set it to 100% an hour later it reports 94% but still low salt despite measuring 5000 ppm
9.0
FC
0.5
CC
7.3
pH
0.01
CSI
11.0
FC
0.5
CC
7.2
pH
-0.09
CSI
Changed pump hours from 9:30-15:30 to 01:00-07:00
Run robot
12.0
FC
1.0
CC
7.2
pH
33 °C
TEMP
-0.09
CSI
Added 2 trichlor tabs to the ones partially dissolved
7.0
FC
-0.05
CSI
10.5
FC
7.3
pH
-0.05
CSI
SWG from 30% to 60% for 6 hours a day
9.0
FC
0.5
CC
7.3
pH
-0.05
CSI
Turned off auto fill 8.560
SWG 30% 6 hours a day
Added 2 tri-chlor tabs in floater
Opened auto fill 8.070
500 mL of 31.45% (20º Be) Muriatic Acid
SLAM done
13.5
FC
0.5
CC
-0.15
CSI
13.5
FC
0.5
CC
-0.15
CSI
1500 mL of Liquid Chlorine • 12%
10.5
FC
0.5
CC
-0.15
CSI
12.5
FC
0.5
CC
-0.15
CSI
Robot and close cover
750 mL of Liquid Chlorine • 12%
13.0
FC
-0.15
CSI
Robot and open cover
17.0
FC
-0.15
CSI
1250 mL of Liquid Chlorine • 12%
12.0
FC
-0.15
CSI
576 mL of Liquid Chlorine • 12%
14.0
FC
-0.15
CSI
18.0
FC
-0.15
CSI
18.0
FC
-0.15
CSI
Brushed
Robot
2304 mL of Liquid Chlorine • 12%
8.0
FC
-0.15
CSI
1000 mL of Liquid Chlorine • 12%
13.0
FC
-0.15
CSI
3000 mL of Liquid Chlorine • 12%
6.0
FC
-0.15
CSI
Turned off SWG
Start SLAM
6.0
FC
-0.15
CSI
7.0
FC
0.5
CC
-0.15
CSI
10.0
FC
0.0
CC
-0.15
CSI
500 g of Dichlor
Changed pump/SWG to on all the time to bump up FC until I can gel liquid chlorine on Monday
2.0
FC
0.0
CC
7.2
pH
-0.15
CSI
Run robot
Increased SWG to 6 hours at 100% from 4 hours
750 mL of Liquid Chlorine • 6%
9.0
FC
0.0
CC
7.2
pH
110
TA
600
CH
40
CYA
4600
SALT
29 °C
TEMP
-0.15
CSI
Ran robot
600 mL of 31.45% (20º Be) Muriatic Acid
14.0
FC
0.0
CC
7.6
pH
0.33
CSI
5618 mL of Liquid Chlorine • 6%
SWG 100%
0.0
FC
7.2
pH
-0.07
CSI
405 mL of 31.45% (20º Be) Muriatic Acid
1000 mL of Liquid Chlorine • 6%
4.0
FC
0.0
CC
7.4
pH
0.13
CSI
SWG 60%
9.0
FC
29 °C
TEMP
-0.07
CSI
7.0
FC
7.2
pH
-0.19
CSI
Increased SWG 40% to 100%
13.0
FC
0.5
CC
7.2
pH
-0.19
CSI
Run robot and clean corners
7.0
FC
0.5
CC
7.3
pH
-0.10
CSI
Reduced SWG to 40%
BackwashedCleaned Filter
Added 5 trichlor pucks in floater to add CYA
600 mL of 31.45% (20º Be) Muriatic Acid
5.0
FC
0.0
CC
7.8
pH
130
TA
20
CYA
0.40
CSI
5.0
FC
7.8
pH
0.31
CSI
Run robot
Increased SWG to 50%
500 mL of 31.45% (20º Be) Muriatic Acid
4.0
FC
7.8
pH
22 °C
TEMP
0.31
CSI
Run robot
500 mL of 31.45% (20º Be) Muriatic Acid
SWG 10% 4 a day
12.0
FC
0.55
CSI
SWG back on 100% 5 hours a day
600 mL of 31.45% (20º Be) Muriatic Acid
6.0
FC
8.2
pH
0.55
CSI
8.0
FC
7.8
pH
0.15
CSI
Run robot
Ran robot
550 mL of 31.45% (20º Be) Muriatic Acid
8.0
FC
7.8
pH
12 °C
TEMP
0.15
CSI
Backwashed
600 mL of 31.45% (20º Be) Muriatic Acid
8.0
FC
1.0
CC
8.2
pH
11 °C
TEMP
0.53
CSI
Ran robot
15.0
FC
13 °C
TEMP
-0.12
CSI
900 mL of 31.45% (20º Be) Muriatic Acid
17.0
FC
-0.09
CSI
Ran robot
350 mL of 31.45% (20º Be) Muriatic Acid
23.0
FC
1.0
CC
15 °C
TEMP
-0.09
CSI
500 mL of 31.45% (20º Be) Muriatic Acid
Reduce run time to 2 hours and SWG to 0%
25.0
FC
0.17
CSI
600 mL of 31.45% (20º Be) Muriatic Acid
Reduced pum & SWG 5 to 4.5 hours
500 mL of 31.45% (20º Be) Muriatic Acid
13.0
FC
0.17
CSI
9.0
FC
0.5
CC
7.5
pH
0.17
CSI
Backwashed
500 mL of 31.45% (20º Be) Muriatic Acid
Ran robot
80 mL of 31.45% (20º Be) Muriatic Acid
2200 mL of Liquid Chlorine • 12%
4.0
FC
0.5
CC
7.5
pH
0.17
CSI
SWG 70-100% 5 hours a day
500 mL of 31.45% (20º Be) Muriatic Acid
5.0
FC
7.5
pH
0.17
CSI
SWG 60-70% for 5 hours a day
6.0
FC
0.0
CC
7.4
pH
0.08
CSI
Calibrated pH meter
SEG 100->60%
500 mL of 31.45% (20º Be) Muriatic Acid
9.0
FC
0.5
CC
7.5
pH
0.17
CSI
Increased SWG 50-100%
7.0
FC
0.5
CC
7.4
pH
0.08
CSI
Increased SWG 30-50% 5 hours
7.0
FC
7.3
pH
-0.02
CSI
550 mL of 31.45% (20º Be) Muriatic Acid
12.0
FC
7.5
pH
0.17
CSI
13.0
FC
0.5
CC
-0.02
CSI
10.0
FC
0.5
CC
7.3
pH
-0.02
CSI
Turned on SWG at 100%
Pump on 10:00 to 20:00 at 1000 rpm
600 mL of 31.45% (20º Be) Muriatic Acid
7.5
FC
0.5
CC
7.6
pH
60
CYA
0.27
CSI
11.0
FC
0.5
CC
-0.09
CSI
12.0
FC
0.5
CC
-0.09
CSI
Turned off auto fill 8065
13.0
FC
-0.09
CSI
550 mL of Liquid Chlorine • 12%
Back washed
Opened auto fill 7704
13.0
FC
-0.09
CSI
17.0
FC
1.0
CC
-0.09
CSI
2250 mL of Liquid Chlorine • 12%
9.0
FC
-0.09
CSI
16.0
FC
-0.09
CSI
1.3 L of Liquid Chlorine • 12%
13.0
FC
0.5
CC
-0.09
CSI
15.0
FC
-0.09
CSI
576 mL of Liquid Chlorine • 12%
14.0
FC
-0.09
CSI
Run robot
16.0
FC
-0.09
CSI
1 L of Liquid Chlorine • 12%
13.0
FC
1.0
CC
-0.09
CSI
21.0
FC
-0.09
CSI
Set SWG to 1%
Set pump to 1050 rpm
Turned off auto fill 7703