Home

Volume: 15000 Gallons
Build Type: Plaster
3.0
FC
0.0
CC
7.4
pH
90
TA
550
CH
60
CYA
82 °F
TEMP
0.03
CSI
3 ppm FC • SWG  30 hrs @ 30 %
1.0
FC
0.0
CC
8.9
pH
90
TA
550
CH
60
CYA
82 °F
TEMP
1.50
CSI
3.0
FC
0.0
CC
7.7
pH
60
TA
550
CH
60
CYA
82 °F
TEMP
0.08
CSI
16 oz of 31.45% (20º Be) Muriatic Acid
3.0
FC
0.0
CC
8.4
pH
70
TA
550
CH
60
CYA
82 °F
TEMP
0.85
CSI
8.0
FC
0.0
CC
7.2
pH
40
TA
550
CH
60
CYA
72 °F
TEMP
-0.72
CSI
10 oz of Dry Stabilizer
1.5 ppm FC • SWG  8.3 hrs @ 55 %
2.5
FC
0.0
CC
7.6
pH
80
TA
500
CH
90
CYA
80 °F
TEMP
0.02
CSI
7.4
pH
-0.22
CSI
10.0
FC
0.0
CC
7.2
pH
80
TA
575
CH
62 °F
TEMP
-0.40
CSI
5.0
FC
0.0
CC
7.4
pH
70
TA
400
CH
70
CYA
87 °F
TEMP
-0.22
CSI
7.4
pH
-0.14
CSI
Vacuumed Brushed Cleaned Filter
0.75 gal of 31.45% (20º Be) Muriatic Acid
6.0
FC
8.4
pH
70
TA
400
CH
40
CYA
87 °F
TEMP
0.83
CSI
2.0
FC
0.0
CC
7.2
pH
60
TA
350
CH
50
CYA
89 °F
TEMP
-0.48
CSI
2.0
FC
1.0
CC
6.8
pH
60
TA
350
CH
60
CYA
89 °F
TEMP
-0.86
CSI

Hot tub

Volume: 400 Gallons
Build Type: Plaster
7.0
FC
0.0
CC
7.2
pH
70
TA
200
CH
100 °F
TEMP
-0.58
CSI
0.5
FC
0.5
CC
5.2
pH
10
TA
70
CYA
102 °F
TEMP