Recent content by wingnut4life

  1. W

    Pool Pump Wont Turn On. Brand new motor.

    Thank you Jim and James. Its my timer. The L1 feed was dead at the pump. I tested each feed at the input into timer and both feeds were fine from breaker. Out of the Timer to the motor the L1 feed was dead as could be. Luckily its only the timer and not the breaker. Have a replacement one...
  2. W

    Pool Pump Wont Turn On. Brand new motor.

    I do not but I will get one tomorrow morning when I start working on it. The model is a PF1102T timer.
  3. W

    Pool Pump Wont Turn On. Brand new motor.

    Jim & James, That's what I was kind of expecting myself. Just looking for some feedback before shelling out for the new timer or breaker. I am going to go back and fully test tomorrow morning with the wires off the pump to test each individually as well as test everything at the timer like...
  4. W

    Pool Pump Wont Turn On. Brand new motor.

    Jim, Thanks for information. I will double check that and make sure. Have not messed a lot with 240 volts so I will validate what I see. When you say "Even if you are missing L1 or L2, you will still read about 120 VAC on each lead when the motor is connected." Is that true with the timer...
  5. motor.jpeg

    motor.jpeg

  6. W

    Pool Pump Wont Turn On. Brand new motor.

    Hello all. I am new to the forum but have used it in the past for advice. Thanks for all to previous unknown help you all provided. So here is my issue. I have a motor that was starting to go out on my hayward pool pump. We just had a bad storm, and the pump tripped the breaker. Day after...