Westovers's latest activity

  • W
    Westovers replied to the thread No Cell Power 2?.
    Thank you Allen @ajw22. You were right: re-soldering that particular connection has the board operational again. For the future... I...
  • W
    Westovers replied to the thread No Cell Power 2?.
    I will try just re-soldering for now... But what about my fuse question? Should I replace the 20A fuse with a 15A fuse to prevent this...
  • W
    Westovers replied to the thread No Cell Power 2?.
    Do I have to replace the relay that is connected to the bad joint, or just re-solder the joint?
  • W
    Westovers replied to the thread No Cell Power 2?.
    I'm sorry, I now realize you were talking about the component opposite the failed solder joint... I thought I just needed to re-solder...
  • W
    Westovers replied to the thread No Cell Power 2?.
    Could you please elaborate? What and where exactly is the 'relay' you are referring to? I am very inexperienced with working 'under the...
  • W
    Westovers replied to the thread No Cell Power 2?.
    If it is, it is VERY VERY slight... Do you still think it needs replacing?
  • W
    Westovers replied to the thread No Cell Power 2?.
    You were right James--one bad solder joint. This is the second board this has happened to (I'm replacing this with my first one...
  • W
    Westovers replied to the thread No Cell Power 2?.
    Is it possible that the actual cell is just dead/done? No way to diagnose which it is--the board or cell--without taking them out?
  • W
    Westovers replied to the thread No Cell Power 2?.
    I've never soldered before... Any particular YouTube you could direct me to for this?
  • W
    Is there a way to diagnose what is wrong without taking the circuit board out? I have a voltimeter...