Recent content by Venison

  1. V

    New T cell still not working?

    When its off because of low temps, it says its off because the temp is too low. It's not saying that at all. It is saying the exact same thing as before it was replaced. The old one (also a T 15) went bad a week - 10 days ago during a warm snap. Is it possible I got a bad cell? Thanks
  2. V

    New T cell still not working?

    Yeah mine does the same. It currently says 56 degrees. The one I replaced stopped working about a week ago when the water was 62. Its saying the same thing the old was saying before I replaced it. "chlorinator off test salt level" and ""check system very low salt"
  3. V

    New T cell still not working?

    I installed it hump up just like the old one. Saw on an old thread that maybe the hump needs to be down? Thanks
  4. V

    New T cell still not working?

    So I just replaced my Hayward T 15 cell with a different brand. Installed it with no problems. At first salt level read 0000, then went back to the "chlorinator off test salt level" and ""salt level very low". Did I miss something during install? I'm hoping it just takes a little time before...
  5. V

    Want to raise water level

    You are correct Dirk I meant to say skimmer. And thanks for the reply. Would it hurt to turn the filter motor up higher? Any body had luck with one of those “vortex” things?
  6. V

    Want to raise water level

    I have a fiberglass 15,000 gallon with spillover spa. I want to raise the water level for no other reason than it bugs me that there is 6 or so inches of pool wall showing between the surface of the water and the bottom of the coping. The problem is that when I raise the water to the top of the...
  7. V

    No cell power 2

    Sorry guys, it is a Hayward Prologic
  8. V

    No cell power 2

    Just put a new swg in this spring under warranty. Threw this code yesterday and not sure where to start? I cut the whole thing off at the breaker box for a couple minutes and nothing changed. My installer has yet to call me backThoughts? Thanks Jeff
  9. V

    Clorox salt?

    Just used Clorox brand for the first time yesterday and noticed this morning that for the first time ever, the salt had not completely dissolved overnight but there was still a couple small “piles” on the bottom of the deep end. Also noticed that the salt reading on both the remote and wall unit...
  10. V

    Panel says (Hayward) chlorinater is "off"

    I've scrolled through every menu and I'll be darned if I can figure out how to turn it "on"! Fwiw, it took an algae bloom for me to realize it was even off. I turned the super chlorinater on per my builders instructions while shocking it.
  11. V

    Best setup for outdoor stereo system

    I know this is an old thread, but I'm looking as well!
  12. V

    Spa auxiliary blower not working

    Thank you Mark I'll check that out and will also add equipment models to my sig. Jeff
  13. V

    Spa auxiliary blower not working

    Hey Mark sorry to be so vague. I'm out of town and obviously new to this pool thing. Can't remember the model but I can control it from either the hand held remote or the panel. And by spa I do mean the jets. Seems like maybe there is an issue with the aux jets and the heater is cutting off...
  14. V

    Spa auxiliary blower not working

    Hayward. And yes for the spa jets.
  15. V

    Need a good hand vaccum, any recs