Recent content by TVGREEN23

  1. TVGREEN23

    Raypak 206A Millivolt Trouble Shooting

    So I have seemed to fix the gas build up problem thanks to yalls help however the heater is still very tempormental. Not sure what the driving cause is behind this but seems as though getting it initially started is a breeze. Once it starts warming up it will usually kick off around 94-95...
  2. TVGREEN23

    Raypak 206A Millivolt Trouble Shooting

    So just to follow up guys I replaced the rollout switch and the water pressure switch after running a few continuity test. The heater is up and running now and my girl couldn't be happier. I am experiencing two problems though that I would love some expert advice on. First off seems as though...
  3. TVGREEN23

    Raypak 206A Millivolt Trouble Shooting

    @JamesW @Pool Clown @swamprat69 @agw22 Thank you all for the responses. Sounds like I am headed on the right track. Going to get a continuity meter today in order to test the limit string as suggested. Glad to hear that it is not the thermostat itself as that was a major concern of mine...
  4. TVGREEN23

    Raypak 206A Millivolt Trouble Shooting

    New to the Forum but not completely new to pools. Lucky enough to grow up with one in my backyard and Pops had me working on it young. Now that I have moved back into my childhood home with my fiance, I am trying to knock off the dust a bit lol. Im good with cleaning the pumps and filters but...