Recent content by stedgar

  1. S

    Pool vac hose pulling out of wall fitting

    I guess I could ziptie the hose to the fitting flap to stop it from pulling out and call it a day.
  2. S

    Pool vac hose pulling out of wall fitting

    My pool vac hose is pulling out of the pool vac lock wall fitting. I have made sure when I inserted the hose into the wall fitting, that the tab on the fitting door is seated onto the hose rib. For some reason, the vac keeps pulling the hose out. Are there other types of fittings that I can...
  3. S

    Pentair (Sta-Rite) Intellipro #013004 3 HP VSP

    I have tried to find the Seal Plate and the Tank Body Assembly and NO ONE has any in stock that I have contacted. We have removed and replaced the oring, siliconed it, etc. and it still leaks. All we cna figure is either the seal plate or the tank body assembly is warped. No visible cracks...
  4. S

    Pentair (Sta-Rite) Intellipro #013004 3 HP VSP

    Hello Group. I have the above pump and it has developed a leak where the metal band joins the 2 cases together. The parts that I need, I cannot find. I have searched high and low. I have already replaced the seals and orings. I just need the 2 cases. The seal plate and the tank body...
  5. IMG_1525.JPG

    IMG_1525.JPG

  6. IMG_1526.JPG

    IMG_1526.JPG

  7. IMG_1527.JPG

    IMG_1527.JPG

  8. IMG_1530.JPG

    IMG_1530.JPG

  9. S

    Pentair Sta-Rite Intellipro VSP Tank Body Assembly

    I have been battling a leaking pump for months. I cannot seem to get the leak stopped. Have even removed the entire pump and taking it to a pool repair business, and they can't fix it. Call to Pentair Customer Service and they are telling me that the Tank Body Assembly must be warped and need...
  10. S

    Salt Water Pool - TDS and Salt Reading Ranges

    So 2400 to 3400 ppm is the correct range for SALT?
  11. S

    Salt Water Pool - TDS and Salt Reading Ranges

    Hello. I purchased a meter to quickly check my pool salt readings. Basically there are 2 settings, one TDS and one for SALT. What is the range these readings should be?
  12. S

    Pentair Intellichlor IC40 no Power, pops fuse!

    Update. Surge board came in today. Prior to taking the panel apart, went and pulled the IC40 off and acid washed the plates. All clean now. Took panel apart and replaced the surge board. Put every thing back together, turned power on and fired up the pump. All works great! Thanks again Jim!
  13. S

    Pentair Intellichlor IC40 no Power, pops fuse!

    Jim, Tested the 2 outputs from the transformer and the reading was 31 volts. This is inline with the spec. So, it appears to be the IC board. So the hunt is on for a new board. Thank you Jim for your help. Steve
  14. S

    Pentair Intellichlor IC40 no Power, pops fuse!

    Thank you Jim. I spoke to Tech Support at Pentair, they seem to think it is the transformer. I have to pull out the 2 wire legs that go from the transformer to the breaker and the board and test them to see if I get 22 to 39 volts AC. If I do not get those readings, then the transformer is...
  15. S

    Pentair Intellichlor IC40 no Power, pops fuse!

    Hello. My found out today that my IC40 was dead, no lights. Opened panel and observed the circuit breaker was tripped. When I reset the circuit breaker, I hear a hum and then the breaker pops instantly. I unplugged the IC40 and tried to reset the breaker. Same results. I am thinking that the IC...