Recent content by riverlvr

  1. R

    Pentair IntelliPh Circuit?wiring supply issues

    The company name is TE.com , part # for plug is 770759-1 (08P MINI UMNL PLUD HSG) , the pin socket part # is 1-794407-0 ( MINI UMNL SOK 20-16 AWG AU LF) they also showed the connector for the circuit board, however I did not need that as I had purchased a new board. Crimper was from Amazon...
  2. R

    Pentair IntelliPh Circuit?wiring supply issues

    Ok, so my new plug and connector pins finally arrived. I also purchased a crimper for the connectors and clipped the plug off the power box, installed the new connectors and slipped them into the new plug housing. Installed with die-electric grease and all appears to be normal again. Systolic...
  3. R

    Pentair IntelliPh Circuit?wiring supply issues

    So, my update is, after a couple hours searching on the "Google" I am waiting for connector parts to arrive to replace the connector in the Ph box to circuit board. As I stated before I have a new circuit board. I am going to use dielectric grease on the contacts after replacement and see where...
  4. R

    Pentair IntelliPh Circuit?wiring supply issues

    Ok, here are some pics.
  5. 20201031_095647_HDR.jpg

    20201031_095647_HDR.jpg

  6. 20201031_095628_HDR.jpg

    20201031_095628_HDR.jpg

  7. 20201031_095623_HDR.jpg

    20201031_095623_HDR.jpg

  8. 20201031_095510.jpg

    20201031_095510.jpg

  9. 20201031_095500.jpg

    20201031_095500.jpg

  10. R

    Pentair IntelliPh Circuit?wiring supply issues

    This will be the 3rd time over approx 4 years that the connector from the power supply to the IntelliPh circuit board overheats and melts. I have had this occur not only on original unit but replacement (complete new unit). I have also replaced 1 control unit separately. The overheated pin in...
  11. R

    Cracked Fiberglass Stairs - Best Epoxy? Help me plan?

    You might try MarineTex. It is an amazing product that is the strongest epoxy product I have ever used!! Saved my butt numerous times. Can be used with additional fiber mat too.
  12. R

    Issue with communication with Easy Touch (Model 2 I believe) replacement indoor wired panel and Intelliflo 4x160 pump.

    Ok, thanks. I'll give Leslies a shout and see what they have to say. Thanks again and I'll post the outcome. Jim
  13. R

    Issue with communication with Easy Touch (Model 2 I believe) replacement indoor wired panel and Intelliflo 4x160 pump.

    So the plot thickens eh? What is involved in re-flashing/updating firmware?