Recent content by PeteT1

  1. P

    Repair or replace AquaRite system

    Thanks for the reply. Nice info in one place. I guess as long as I can still find replacement boards for the controller if I have a failure, the investment in a new t-15 cell won't be lost.
  2. P

    Repair or replace AquaRite system

    Hi guys, Need some advice. I have a 15 year old Goldline Aqua Rite SWC with a T15 cell (10 years old). It now needs a new cell and a flow switch. Two years ago I successfully repaired the pcb, replacing a burnt resistor. Should I fix this system (about $400 I think) or replace? Thanks - Pete
  3. P

    Cloromax in pool

    Thanks for the great replies guys. I did try raising the FC level to about 20 for 36 hours. I also thought that if this stuff lives in strong concentrations of FC, Shocking would have little effect. I did put about 3.5 jugs of the Cloromax tainted bleach in the pool. Sun, time, shocking and...
  4. P

    Cloromax in pool

    Unfortunately no amount of shocking or filtering will get rid of the additives in cloromax bleach. The smell and feel of the water has not changed. Anyone else fighting this? Looks like my only solution may be to completely drain/refill.
  5. P

    Cloromax in pool

    Thanks for responding. Maybe not so slimy, but definitely has a smell to it. Here are the current test results: FC - 8 ph - 7.4 TA - 100 CA - 260 Salt - 2600 CYA - 60 Not running the SWG yet.
  6. P

    Cloromax in pool

    Ok. Let me start by saying I screwed up. Opened pool last week, picked up a couple 3 jug cases of the old standby - Clorox bleach at Costco, only to find out it was replaced with the Cloromax additive. Pool water is balanced, looks beautiful and is slimy and smells gross. I have tried draining...