Recent content by Ozzsp250

  1. O

    New to Pool Chemistry

    Just taken readings after adding 1 gal muriatic acid and chlorine allowing the pool to run overnight through its normal cycle. FC 6-7 CC 0 PH 7.9 TA 220 CH 375 CYA 65 Salt 3100 Water temp is 74F So the TA is still very high, I repeated this test with same result.
  2. O

    New to Pool Chemistry

    It is a salt pool using a IC40 salt generator. No algae at this time but I notice white flakes on the steps where the pool cleaner doesn't access. I should have noted salt is 3100 ppm
  3. O

    New to Pool Chemistry

    I used my new just received TF-100 test kit today and know are trying to use pool math to correct chemical pool imbalance and need advice on using pool math or the app but I'm digitally challenge. My results: FC 1.5 CC 0.5 PH 8.5 TA 250 CH 250 CYA 60 Water temp is 74F My pool/Spa combo is...
  4. O

    New to forum with questions regarding by pool equipment / control

    Ok I have completed the changes on my system. I use the pump filter relay to supply 240 vac power to Aux 1 relay [was spa light but does not work] which I have set as a timer within the Hayward configuration setup. I then use the Aux 1 timer to drive the Pentair Salt Cell. The Pentair VSD pump...
  5. O

    New to forum with questions regarding by pool equipment / control

    Just joined the forum after purchasing a house with an existing in ground swimming pool and spa. I doing some research on my pool equipment. Current controller is Aqua Logic PS-4, cartridge filter, Pentair Variable Speed pump for pool and spa, Pentair Salt generator cell. What I don't like is...