    Rock/Waterslide Feature Resurfacing

    Has anyone resurfaced a water slide? We had a plant leak sap and crack the surface.
  2. K

    Pentair intellichlor Dead

    Thanks for your advice. I will try all of this. I’ll post here again if it doesn’t resolve. Thanks again.
  3. K

    Pentair intellichlor Dead

    I do have an EZ touch with built in power supply. And yes, I’m refering to screen logic. The black wire is on the power supply wire to the SWG. Pentair part #520724. There are four wires. (White/blue/black/red. Black is the burnt wire) I took pictures but I can’t figure out how to make them...
  4. K

    Pentair intellichlor Dead

    I noticed my Chlorinator led lights weren’t operating. Checked the cell and it seems to be dead. When I opened the EZ touch I noticed the black wire connector to the circuit board was burned. I obviously need to replace the wire, but is there additional problems I should look for so I don’t hook...
  5. K

    Pentair Whiserflo Pump

    When I'm running both, I split the difference so maybe I do need this size? If I keep this size, what additional things should I do when I replace the motor? For example, are there seals I should replace, etc?
  6. K

    Pentair Whiserflo Pump

    I always felt it was a little overkill. The waterslide is actually a slide and water fall combo rock feature. You can divert the water equally or to one feature (slide/waterfall). It stands about 6ft tall and the pump is seated behind it out of sight. It draws separately from the main...
  7. K

    Pentair Whiserflo Pump

    I have a Whisperflo Pump dated from 2007, model number: WFE-8. It's a dedicated pump specifically for a waterslide feature for the pool. I turned it on to filter some water through it. It buzzed for a moment, then it fell silent and it's completely dead now. I'm able to manually rotate impeller...
  8. K

    Pentair WhisperFlo

    I have a Pentair WhisperFlo (Model No. WFE-8) as a pump. A couple weeks ago when I turned it on, all I heard was buzzing. I quickly turned it off, then back on and it worked perfectly. This past weekend, I turned it on. Again, the buzzing was heard, but before I could turn it off it went dead...
  9. K

    Water featre pump is kaput

    I'm going to try replacing the capacitor first.
  10. K

    Water featre pump is kaput

    I have a Pentair WhisperFlo (Model No. WFE-8) as a pump for a water feature (slide/waterfall). A couple weeks ago when I turned it on, all I heard was buzzing. I quickly turned it off, then back on and it worked perfectly. This past weekend, I turned it on. Again, the buzzing was heard, but...
  11. K

    Pentair Master Temp 400 problems

    Bypass valve was broken. The piece was stuck in a Jandy valve between heater and SWG. Replaced that and the Thermal Regulator. Heater works like a charm! Thanks everyone for their help. I love this website!
  12. K

    Pentair Master Temp 400 problems

    Thanks to everyone for their advice, as soon as I get the bypass valve, I'll give it a try. Hopefully this resolves our heater problem. Otherwise I'll be adding to this thread.....
  13. K

    Pentair Master Temp 400 problems

    I found this old link: Mastertemp bypass valve Would you say this is accurate as far as a step by step guide? Anything you would add or discourage?
  14. K

    Pentair Master Temp 400 problems

    Has anyone replaced a bypass value on a master temp?
  15. K

    Pentair Master Temp 400 problems

    From what I've been reading, Salt Water Pools and Pentair Master Temps have this problem with regulators frequently. I ordered one and will replace as soon as I get it. Oddly I had a service tech come out last year (5/15) and all he ended up doing was replacing the regulator. Amazing that I have...