Recent content by Jknelson65

  1. J

    Solar question

    Initial issue - spa equalizing overnight. Tech replaced check valve and chlorinator, spa still equalizes. Add to that, pump basket wouldn’t fill completely AND chlorinator won’t fill unless cap removed. They have now completely rebuilt suction side plumbing (valves and all connections). Spa...
  2. J

    Solar question

    FINALLY! Another set of eyes noticed that the pump wasn’t sitting “flat/level”. Leveled pump, lubed union o-ring and now everything is back to “normal”...
  3. J

    Solar question

    Anybody know where these can be found?
  4. C857D58A-2713-4BA4-B08F-41FA643D50F7.jpeg

    C857D58A-2713-4BA4-B08F-41FA643D50F7.jpeg

  5. J

    Solar question

    Tried the suggestion about turning off solar, ramping up pump speed and blocking returns. Seemed to have resolved 99.9% of bubble issue. NOW pump primed, ran for @ 5 hours and all of a sudden flow to returns and spillover to spa reduced noticeably. Checked and filter basket was 1/2 full. Shut...
  6. J

    Solar question

    Weird issue, pump basket water level drops after an hour or so (no air in filter when I bleed it), spa equalizes after pump off within an hour. Check valves all replaced, Pentair valves all rebuilt, checked piping with suds. Also, when I run solar I get bubbles all day, ramp up pump speed and...
  7. J

    Solar question

    Maybe a stupid question, but if I had an underground suction side leak letting air into the system wouldn’t it leak water when the pump is off?.
  8. J

    Solar question

    Possible to re-apply pvc cement to all connections, just to be on safe side?
  9. J

    Solar question

    apparently i had suction side leaking in plumbing. During that troubleshooting process we found that 2 of the spa returns (they have a "reducer" in the line) were clogged. One of them was actually pulling water from spa into the line. Got those all corrected, and all suction side leaks have...
  10. J

    Solar question

    They were out this morning and lubed/replaced all o-rings..everywhere. Found a return in spa that was actually drawing water back into the return! Actually found 2 of them filled with “debris”...🤦‍♂️
  11. J

    Solar question

    2” plumbing Hayward TriStar VS SP3202VSP Motor RPM = 3450 Curve A = 64 GPM Curve B = 38 GPM Curve C = 85 GPM
  12. J

    Solar question

    Not sure how to figure that...I’m a dummy
  13. J

    Solar question

    O-ring and pump basket lid are fine. Something odd started showing up...pump basket randomly losing “prime”. Pump running fine and suddenly the water level in basket drops, turn off pump, re-prime basket and it’s fine for a while. Then randomly it wil drop again...
  14. J

    Solar question

    I’ll double check that tomorrow. I have Jacks 327 lube...
  15. J

    Solar question

    I only get the bubbles when solar is running...