    Gunite mistake on shelf/ledge depth - what are my remedies?

    Thanks for everyone who gave their input and advice. Very much appreciated. The pool company is offering some money off the pool in addition to the one inch chip out. What do you think would be a fair amount? It will not be at the right depth but I think I will be okay with it.
  2. B

    Gunite mistake on shelf/ledge depth - what are my remedies?

    The step we added so that we could have the requested depth with 12 inches of water.
  3. B

    Gunite mistake on shelf/ledge depth - what are my remedies?

    Photo with a 12 1/4 inch length ruler
  4. B

    Gunite mistake on shelf/ledge depth - what are my remedies?

    Here are the communications from the pool builder: " I’ve talked with the team and it looks like we can remove about an inch of gunite from the shelf area. If you then keep the water an inch higher (slightly above mid tile line) then we will have made up two of the three inches missing and you...
  5. B

    Gunite mistake on shelf/ledge depth - what are my remedies?

    Hi- no I wanted 12 inches of water so the gunite should have been at 15" with room for tile.
  6. B

    Gunite mistake on shelf/ledge depth - what are my remedies?

    Yes, and I would love the group's advice. They said they could remove one inch of gunite through "chipping." And we could keep the water line one inch higher. They said this would get us 11" of water. They are asking how we feel about this. My main issue is that I wanted the water to be...
  7. B

    Gunite mistake on shelf/ledge depth - what are my remedies?

    Is that from the bottom of the shelf to the top of the coping? Thanks!
  8. B

    Gunite mistake on shelf/ledge depth - what are my remedies?

    I appreciate this. You are absolutely right.
  9. B

    Gunite mistake on shelf/ledge depth - what are my remedies?

    It’s not the greatest photo.
  10. B

    Gunite mistake on shelf/ledge depth - what are my remedies?

    I believe he meant that it was the first time they had screwed up a tanning ledge depth on his watch.
  11. B

    Gunite mistake on shelf/ledge depth - what are my remedies?

    Thank you for all your advice!!! I do have some pictures. I wish I had thought to measure the rebar. Should I be concerned about jackhammering causing structural instability in the pool? Thanks again! Suzanne
  12. B

    Gunite mistake on shelf/ledge depth - what are my remedies?

    Hello! Right after our gunite crew left today, I went out and immediately noticed that the tanning ledge looked too shallow. It was supposed to be 15" and is 12". The project manager came right out and said this was a case of first impression for him. He is calling his manager. What are my...