Recent content by aviator79

  1. A

    Intex SWG Service Light - Fixed!

    Pull the whole circuit board out. I cant tell from pic if anything wrong and that CB looks different than mine but I would suspect a bad capacitor or something just like I had.
  2. 16240489113387846371881538423909.jpg

    16240489113387846371881538423909.jpg

  3. A

    Cloudy pool ~0CYA ~8.0ph

    Pool is AG 15x30x4 so ~10k gallons. Using intex SWG/sandfilter/pump (Intex 2650 GPH Saltwater System & Sand Filter Pump Set | 28681EG (56681EG)) Opened pool in April but did not start running pump due to issues until about a month ago so got full of crud and turned green. Repaired sand filter...
  4. 16240485931954760905822120261907.jpg

    16240485931954760905822120261907.jpg

  5. A

    Intex SWG Service Light - Fixed!

    Figured post here even though old thread rather than make a new one.. Just fixed mine (I think) Was a missing capacitor at c13 by the terminals top left in first pic. It is a 100uf 50v. Soldered new one on with negative lead toward terminals. Removed bad terminal forks, soldered new ones on...
  6. 20210528_005451.jpg

    20210528_005451.jpg

  7. 20210524_215501.jpg

    20210524_215501.jpg

  8. A

    Capacity sand filter intex 56681EG SWCG/filter/2650gph pump

    So I am finally going to replace the sand in my intex sand filter after filling in 2013. Didn't use for a year or two so sand has 5-6 season on it and probably could use replacement. I struggle to get pool crystal clear at the beginning of the season and feel new sand could help. I also only...
  9. A

    Repair cracked end SWG electrode, plates touching Intex

    Well it worked. I will try to upload pics but if other have this issue you can fix. If cant plastic welt could try zip ties or even gorilla or electrical tape...GOOD LUCK! Save me some money.
  10. A

    Repair cracked end SWG electrode, plates touching Intex

    I cant get pics posted but I am assuming the plates should not touch so I plastic welded end together with plastic spacers. Now with only two connector prongs and 3 plates IDK if this was the right way to repair it. I do not have a new one to compare it to. As far as I can tell they look...
  11. A

    Repair cracked end SWG electrode, plates touching Intex

    So I was getting a low salt warning after setting up pool. I just installed new liner. Tested salt and about 3200ppm so thats good. Removed plate and end is cracked at end and plate are touching so going to repair and see if works.
  12. A

    Re leveling bottom of oval 30x15 AGP before new liner install?

    I guess it looks like part of the problem is sides or ends are not far enough out causing the squiggle on side which causes more force on side beams and hence why they angle and stick up. This seems like may be a lot of work to fix right so again im tempted to just clean foam and install liner...
  13. A

    Re leveling bottom of oval 30x15 AGP before new liner install?

    Edit so removed bottom foam from edge and pool is pretty shot so 3rd post on will just be how i fixed for now. Pool needs too much work to properly fix where might as well buy new one so just going to do what i feel will work best to at least work for this season. So i made it thru last...
  14. 1467065041217.jpg

    1467065041217.jpg

  15. 1467065005842.jpg

    1467065005842.jpg