Bad news about VS motor/pump

Jul 6, 2013
596
Waxahachie, Tx.
Hi everyone, well my situation does not look real good. My Hayward SP2300VSP(now discontinued) appears to be bad. Last night we were not home till late, lots of lighting strikes, came home to no power. This morning pump was not running. Had 240V at the motor terminals, so everything up to that point is good. This model does not have the internal timer. There is a mech timer on the wall that turns on the 240V for the pump and SWG panel together. The pump is completely dead. The new MAX Flo VS pump SP2303VS has an internal timer. Does anyone have suggestion on recommended ways to hook up to control the pump and SWG togerther? Can I still use my exsisting arrangement?
Thanks in advance.
 
Thanks. I know how vfds work. Not trying to be an ***. Hayward told me it was a DC motor, which I said BS. They do make a single phase in single phase out.
Once I installed new pump I tjen had a chance to disassemble the drive. There is a PCB mounted internally to the back of tje motor. The motor is German made by Hanning. They also make the VFD which is proprietary
 
Did you have surge protection for the drive? If not, consider installing it or the next lightning strike, the same thing may happen?
 

Enjoying this content?

Support TFP with a donation.

Give Support
The one Mark recommended is really a good SPD. You can get them from HD for $75 w free delivery on sale...I installed 2 of them, one at each 200amp panel and a flush mounting kit bc my panels are in sheetrock. These SPD's have 80000 amp protection while most others top out btw 20-30K amps...so you get 2-3 times the protection.
 

Attachments

  • SPD2.jpg
    SPD2.jpg
    37.5 KB · Views: 57
  • SPD5.jpg
    SPD5.jpg
    19.7 KB · Views: 57
The one Mark recommended is really a good SPD. You can get them from HD for $75 w free delivery on sale...I installed 2 of them, one at each 200amp panel and a flush mounting kit bc my panels are in sheetrock. These SPD's have 80000 amp protection while most others top out btw 20-30K amps...so you get 2-3 times the protection.
Nice looking install. Just wanted throw out a pic of the old motor nameplate. When i get time gonna tear into it and see whats up