Pool lights stopped working, PX300, iAqualink RS

It seems I should see 120v correct?
Let's slow down here.

By "Control Box" you mean the Aqualink relay?

Looking back at your post, you never found 120V at the transformer. I thought you did.

Go back to your Aqualink panel. Start at the relay that controls the lights.

Post pictures of your open Aqualink panel showing the wiring, breakers, and relays.

Find the wires in the Jandy that are attached to the relay that controls lighting. Then with the lights turned "on" at the Jandy, test those same color wires at the transformer. It should be 120V.

Test if there is 120V going into that relay, it should be at terminal 1 or 3 and to ground or neutral bar.

If not, is there voltage coming at the breaker? Test from the terminal to neutral or ground. Is the breaker tripped?

Is it a GFCI breaker?

Is there a GFCI in the light circuit that is tripped? If there is one on the side of the Jandy cabinet, the lights may have been wired through it and it tripped.
  • Like
Reactions: joel98z

Main filter pump breaker tripped

Thanks!
So, replacing single speed Whisperflo and installing Whisperflo VST:
1--Remove black and red wires from the pump relay and connect the pump's black and red wires directly to pump breaker.
2--Connect green and yellow wires from automation cable from pump to COMM port on surge board.
3-- Do you keep all the wires connected to the J20 COMM port (two reds, two yellows, two greens, two blacks, coming from the salt board and the antenna) alone? Leave them connected right whwere they are?
4--Do you keep the white and yellow wires (coming from the large transformer)connected to the relay?
5--Anything else?

Pump and union leak

Hi! I am trying to open my pool for the first time (just bought my home last winter and this will be our first summer at the house).

I just tried to turn on my pump and it just leaked some water out from it. Is there any hope for it, or do I need to buy a new one?
Login to view embedded media
Also, I just tried to connect all pipes and discovered a union leak. I bought some teflon tape and this union set from Amazon (SP1480BLK Pool Pump Filter Union for Hayward DE and Cartridge Filter Parts 1-1/2 inch Self-Aligning Double Male End Union) to fix it. The pipes were the right size, but the coupling was way too big (the part the rotates to attach both sides). In the end, the teflon tape and using an oil filter wrench closed the leak (not sure for how long). Do I leave as is as it is not leaking for now, or should I just try to find the right union set and change everything?
Login to view embedded media
Thanks a lot for any help! I learned a lot from this site already!

(Failed with first 60 days) First look at Pentair's new IntelliChlor Plus30

I just purchased my “old version” IC40 today to replace the IC60 brick hanging on my plumbing. Hopefully this one will give me more years than the 60 did and then I’ll get the newer version after it’s had a few more years of beta testing 🤞. If it’s anything like their typical product development, they should have 90% of the bugs worked out in about 3-4 years … 🤣

Returns Not Working

I think that the red circled ball valve is closed.

You can try opening it to see what happens.

Maybe it is closed for a reason?

Maybe the lines leak?

Note: The Hayward Dial-A-Flo Valves are gate valves or diverter valves, not ball valves.

View attachment 644537

This was the solution. I never realized that could be opened and closed. The people that closed the pool must have closed it. Thank you JamesW!!

Every year I learn something new. Now it's time to great rid of the green water.
  • Like
Reactions: JamesW

New EVO 614i Robot Pool Cleaner Review

1. Yes, I have a vinyl pool. (20x40 Lazy L) no issues at all.
3. It comes with a 60’ cord
4. I highly recommend the fine filter, it is worth the $50.
5. You can set up in the app a daily schedule to run. I have ours to come on daily at 8am. You’ll get a notification 2.5ish hours later when it’s done.
Thanks for the response Jim.....I will order it online at Marina. Not sure there is any reason for me to call as this thread pretty much answers all my questions.

1746918214664.png

Main filter pump breaker tripped

Connect the pump’s power directly to a dedicated GFCI breaker in the EasyTouch load center or an external breaker panel. You won't use a relay.
Use a two-wire RS-485 communication cable to connect the pump to the EasyTouch COM port to control the pump.

I'm not sure if it standard to connect multiple controls to the com port.

@ajw22 or @Jimrahbe would know.

Pool lights stopped working, PX300, iAqualink RS

Here is a little better picture with wires from transformer disconnected. So this picture shows transformer disconnected from White and black wire coming from control boxView attachment 644850View attachment 644851
The diagram show the low voltages side has two black wires.

You are testing between a white wire and black wire.

Something is confused.

There is a divider between the lower half of the box.

One side should have the colored high voltage wires.

The other side should have the two black low voltage wires.

Identify the wires correctly.

Pool lights stopped working, PX300, iAqualink RS

Find the wires in the Jandy that are attached to the relay that controls lighting. Then with the lights turned "on" at the Jandy, test those same color wires at the transformer. It should be 120V. if not, find out if there is 120V going into that relay, should be at terminal 1 or 3 and to ground or neutral bar. If not, is there voltage coming at the breaker? Test from the terminal to neutral or ground. Is the breaker tripped? Is it a GFCI breaker? Is there a GFCI in the light circuit that is tripped? If there is one on the side of the Jandy cabinet, the lights may have been wired through it and it tripped.

He already confirmed he has 120V at the transformer.


If you have that 120V, you can test each of the blue, grey, yellow wires individually by having one probe on the wire and one on the ground bar, a bare piece of metal in the cabinet.
Blue should read 14, Yellow 13, Grey 12. You won't get those exact numbers in most cases, but it should be close. If you don't see that voltage the transformer is bad.
That is not the way the PX300 works according to this diagram….

1746912207178-png.644828

Attachments

  • 1746917403827.png
    1746917403827.png
    25.6 KB · Views: 1

Pool lights stopped working, PX300, iAqualink RS

Here is a little better picture with wires from transformer disconnected. So this picture shows transformer disconnected from White and black wire coming from control box
Find the wires in the Jandy that are attached to the relay that controls lighting. Then with the lights turned "on" at the Jandy, test those same color wires at the transformer. It should be 120V. if not, find out if there is 120V going into that relay, should be at terminal 1 or 3 and to ground or neutral bar. If not, is there voltage coming at the breaker? Test from the terminal to neutral or ground. Is the breaker tripped? Is it a GFCI breaker? Is there a GFCI in the light circuit that is tripped? If there is one on the side of the Jandy cabinet, the lights may have been wired through it and it tripped.
If you have that 120V, you can test each of the blue, grey, yellow wires individually by having one probe on the wire and one on the ground bar, a bare piece of metal in the cabinet.
Blue should read 14, Yellow 13, Grey 12. You won't get those exact numbers in most cases, but it should be close. If you don't see that voltage the transformer is bad.

My First Pool Kit….Builder Edition

Todays excitement…

IMG_8874.jpeg

A bulkkhead fitting started leaking. The pool was run for barely 4 months last season and put to bed. I opened it Monday. Deadline for swimmers in the water is the 15th, plus I’m stacked with 2 a day openings this week and service on about 10 accounts already opened. It’s gonna be a nailbiter to get this pool right before opening. I think little sleep is in my future….😂
  • Like
Reactions: Newdude

IMG_8874.jpeg

My First Pool Kit….Builder Edition

I think I would forward pics of it all including the inspection sticker and ask the code folks why they think this was passed. I'd share the contractor name with them too.
My assumption is that when inspection took place, it was wired for 120v. It would have passed in that configuration. Then after final when the contractor realized the pump wasn’t working, this mess happened to get the pump to work. As for the lack of GFCI breakers, I can’t explain that one. Inspector was asleep? At this point “powder is being kept dry” for the owner as I’m documenting and correcting. It’s their decision to act legally or otherwise against any and all responsible parties if you catch my drift 😉.

20250510_175822.jpg

Filter