Search results

  1. G

    Replacing pump motor

    I did pull off the impeller and check the vanes and didn't see anything (you can only see so far in them) and also tried blowing them out. If I open all the suction (cleaner/skimmer/main drain) there isn't much difference. BTW, thanks so much for the suggestions. I appreciate it!
  2. G

    Replacing pump motor

    This is what I was worried about... don't want to replace motor only to find out that isn't the issue! :( If i remember right, after cleaning the filter the pressure would be about 15-20psi and now it's only at ~10psi. However, I could be mis-remembering (pretty sure it didn't get down to 10...
  3. G

    Replacing pump motor

    Here are some pics. Valves in order from Left to right are: Cleaner, skimmer, main drain, return and waterfall. Current configuration is how I leave it when not using the pool (cleaner is on, skimmer partial and return on). To switch it to run the waterfall I just turn the return off and the...
  4. 20160720_163210.jpg

    20160720_163210.jpg

  5. 20160720_163759.jpg

    20160720_163759.jpg

  6. G

    Replacing pump motor

    Ok, i was wondering about the impeller as well. I think the WFE4 part refers to the impeller sizing? I'll have to research that more.;) Yes, there are two simple quarter-turn type valves to separately control return into pool and waterfall. I'll try and post some pics later. Thanks.
  7. G

    Replacing pump motor

    Hi all, I don't post much on here but lurk and use it as a resource when I'm having issues. Hopefully you all can help with this one. I have a ~15K gallon SWG pool with three waterfall features (two about 18" above pool surface and one ~28" above), Pentair cartridge CCP520 filter (150gpm)...
  8. G

    Another Aquapure 1400 no flow issue looking for some details

    Just to close this thread out... Received the new sensor today and it fixed the problem. Freaked out a bit at first as I thought I had received/ordered the wrong part. This one has a separate comtroller to pick a program based on your main board and doesn't use the small adapter board...
  9. G

    Another Aquapure 1400 no flow issue looking for some details

    I usually keep the filter pretty clean so pressure stays on the low side. It's currently just under 20psi and I don't remember it getting much above 25psi or so over the summer. Flow out of the returns feels normal to me.. I have taken the whole cell off and the plates are very clean, no...
  10. G

    Another Aquapure 1400 no flow issue looking for some details

    Ok. Tried holding "cal" button again while display shows "wait" (before no flow shows). After about 3 sec green led on circuit board (not the flow led on display) blinks once and then after a while starts blinking again and i still get a no flow display. I took the pump apart to make sure it...
  11. G

    Another Aquapure 1400 no flow issue looking for some details

    Oceansol, pretty sure I already did that for 5 seconds but I'll definitely try again!
  12. G

    Another Aquapure 1400 no flow issue looking for some details

    Hi! I have an Aquapure 1400 which is showing a constant no flow indication. I've done some research and I've already tried cleaning the sensor (wasn't really dirty but it's sparkling now!), disconnected/re-connect the sensor at the board and haven't had much luck so far. I don't get any error...