Search results

  1. P

    How To Test Power from Intellichlor Transformer with EasyTouch

    Hi all, trying to diagnose an issue with my IC40. The lights all flicker for an instant when power is turned on, but thats it. No more lights. Diagnostics on the panel show ok, as well as the little Intellichlor green light on the board. I have the Easy Touch panel and want to test the...
  2. P

    MasterTemp Shutting down few seconds after flame/ignition: LED #5

    All right gang.... finally -- RESOLUTION! Bad control board. Had ordered a new one from Amazon and all is working now. First time i fired it up, ran for about a minute (vs. 15 seconds), and shut down for a few seconds, started up again.. .ran for a bit, shut down.... third time it started...
  3. P

    MasterTemp Shutting down few seconds after flame/ignition: LED #5

    Pool clown, cool tip. Tried that. Heater doesn't run flame long enough to get the temp past 140 or so. Smell is a little off.. like half burned propane or maybe its cooking some rat/mouse somewhere. Additionally, the thermo regulator flew right out... so bypass may be fine. Tomorrow I...
  4. P

    MasterTemp Shutting down few seconds after flame/ignition: LED #5

    All right guys 1) HLS -- No.. same issue after jumping it 2) AGS -- No. same issue after jumping it 3) Thermo - No. same issue after removing 4) Exchanger Breach - No. Removed Lower bolt on manifold and No water -- bolt was dry So. What would you do next? 1) I still have an inkling...
  5. P

    MasterTemp Shutting down few seconds after flame/ignition: LED #5

    Thanks all. I took out the thermo regulator and it was pretty corroded.. in fact part of the copper was just gone. I put it back together without the part, and thought it would run fine if that was issue? Is that correct? Same issue even without the thermo. I am concerned if that copper...
  6. P

    MasterTemp Shutting down few seconds after flame/ignition: LED #5

    Hi all, spent the last several hours disassembling my MasterTemp 200 LP and trying to locate my issue. It seems to be ok for about 5-10 seconds. Blower kicks on, and then ignition, but then shuts down after a few seconds of heat. There was a small nest in the air orifice, cleaned that...