Search results

  1. K

    Auto fill valve replacement

    That is part or Jandy's Levelor system. You should be able to download a manual and parts list off their website
  2. K

    Need advice on choosing a water feature pump

    As per the DOE you can use a waterfall pump that does not exceed 1800 RPM at<30ft or a variable speed pump
  3. K

    Pool store guy says I don’t have normal return jets...

    Google flush mount return eyeballs, usually they only come complete. Wall Fittings - Return Fittings. this company is in Scottsdale
  4. K

    Bulb replacement

    Your junction box should be above water level, so you don't need to plug. Most niches are 1/2-3/4" openings
  5. K

    Intelliconnect Panel Dead

    Check the power to and from Transformer
  6. K

    Pool light

    Pentair, Amerilite
  7. K

    Vacuum Relief Valve Leaking

    This looks like the Helicol vacuum breaker, which can be opened and cleaned. I don't believe there are any parts for this, but a new is HELIOCOL 3/4" Vacuum Relief Valve - Solar Pool Heater Vacuum Breaker | eBay
  8. K

    Pebble Tech install- HELP

    That isn't your resphttps://www.pebbletec.com/contact-us/onsibility. It's there's, and if it is a certified Pebbletech dealer they should take care of it. If the builder subcontracts the plastering then the company is responsible. You can also contact Pebbletech, Contact Us About Pool Surfacing...
  9. K

    Old Navigator - Not circling post re-assembly

    No, it does not. Did you replace the gearbox? Usually you can bring the cleaner just below waterline and leave it hanging and watch for it to rotate. If it doesn't rotate after a while, probably need to clean or replace.
  10. K

    Pump repair... Wrong impeller?

    https://www.inyopools.com/Forum/thread/part-number-for-impeller/
  11. K

    Epoxy Recommendations?

    A & B epoxy. https://www.leaktools.com/ab-epoxy-putty-14-oz-kit-white.html
  12. K

    Help identify skimmer plumbing

    Baker Hydro / Purex Parts - INYOPools.com. It reminds me of a Baker skimmer, where the threaded hole in front goes to main drain and the bottom center or the bottom side goes to pump. They used a special control plate to divert more skimmer or more main drain.
  13. K

    Jandy pump and filter - two way valve

    If you have a skimmer and main drain connected to the valve then it's a 3-way. You can loosen the handle screw and turn the valve handle around so the closed part of the handle is facing the pump
  14. K

    Help identify filter,please!

    I believe that is a mineral system, just can't remember the manufacturer. It was used to add minerals like copper or silver to the pool. You probably could leave alone or cut it out of the system if leaking and not being used. Brain just kicked in it's a Nature 2 system but older
  15. K

    Replacement for FNS PLUS 60

    Just be aware the quad de backwash valve plumbing is opposite of the FNS60
  16. K

    6 Port T Valve Rebuild

    https://www.epoolsupply.com/pages/poolinfloor/
  17. K

    What is my iAqualink System Number?

    Look on the side of the antenna
  18. K

    spa return jets missing?

    Drain the spa down into the pool just below the jets and then turn on jets make sure you have good action out of all jets. These are older jets, and it looks like the face were replastered in. It looks like the nozzles inside could be adjusted up or down and may help
  19. K

    How many tries does it take to properly seat a new motor? I've got a leak

    The Hayward SuperII pump overtime can develop a small crack inside on the top of the pump housing. You would need to pull the assembled motor out and using a small mirror look up in the housing just pass the gasket area, usually it is in the top center
  20. K

    Spa air blower turns off after about 20 minutes, does not appear to come back on unless switched on

    The air blower is preset from the factory with a 30 min. timer. Don't know how accurate this is, but it can be lowered in the device runtime. If the pool builder can't help call Jandy support
  21. K

    Shaft seal leak or something else

    Check the impeller where the screw goes through for cracks and or missing impeller gasket
  22. K

    Tile Strip AKA Cove Strip - Plastic between coping and tile

    It is part of the form on cantilever concrete decks
  23. K

    What is this noise from the pump?

    Sounds like the bearing may be starting to slip on the endbell, hard to tell but testing the motor when it isn't under a loaded condition won't show this condition
  24. K

    What variable speed pump should I buy?

    How many spa jets are in the spa, it may be that the 342001 can't produce enough flow at the higher head that spa jets produce. Otherwise, for just filtration it is a decent pump.
  25. K

    IAqualink solar issue?

    I'm aware of the use of solar priority or heat pump priority when using with a gas heater, but not with each other. You may have to contact Jandy support on that. What does the person who install the iAqualink system say?
  26. K

    Need Pressure relief air valve for blower in spa at condo complex

    Take an amp draw test while the blower is on, some techs will drill small holes in the pipe until they get within the blowers spec's. Putting on a larger blower usually leads to trouble
  27. K

    New Pump and Filter for Old Pool with Poor Circulation

    If you're going to use a VS pump you can easily dial in the optimum speed for your pool use. You probably could go with 1.65 Defender on your setup with 1.5" plumbing
  28. K

    Pentair Mastertemp 400 - water temperature in spa not reaching what it use to

    More than likely the thermistor, if it was a Hi-limit or Thermal regulator you would get a error code and the heater wouldn't run very long. They use a 10K thermistor which you could ohm check at different temperatures
  29. K

    Automatic spa shuttoff after X hours w/ Jandy Aqualink?

    Yes you can setup device runtime to act like a eggtimer