Search results

  1. D

    Dolphin will not climb the walls

    Just a thought, I have a Zodiac, it has 2 modes, one it climbs the walls, one it does pretty much what you describe, it also doesn't like climbing when the bag is full
  2. 2016-06-03 21.10.58.jpg

    2016-06-03 21.10.58.jpg

  3. D

    No tile on steps, spa seat and tanning shelf?

    I thought about it, and had sufficient waterline tiles left to do so, but in the end didn't bother, apologies for the leaf, its windy out :) Dropbox - 2016-06-03 21.10.58.jpg edit:How do you get dropbox files to show in the message?
  4. D

    Using Lithium Hypochlorite to shock

    Lithium Hypo is ludicrously expensive (in OZ anyway) 2KG AU$88 a quick mess in pool math shows 568g LH ($25) vs 1.5L bleach(12.5%) ($1.20) to do the same thing.
  5. D

    Post-Slam/OCLT: FC Loss

    Why do you think you have a problem, your weather shows 30C & sunny, FC loss is to be expected, you have minimal CYA <40 could be 20 ??, 0CC, . What are you afraid of?
  6. D

    Constantly adjusting SWG %

    You will get a little finer adjustment by adjusting run time, either leave on the lower setting and increase run time by 1 hour or leave it on the higher setting and reduce run time by 1 hour test various run times until you get less of a swing. Then as the summer comes you'll need to do it all...
  7. D

    New pool owner, can I do this?

    Im sure you have exhausted all suction side issues. Disconnect the pipe/union/outflow side of the pump, turn it on, this will tell you if the pump is goosed or not, either attach your temp pipe thing and send it back to the pool or prepare to get wet, chances are your filter is blocking any flow...
  8. D

    New pool owner, can I do this?

    Sorry shodges, I was referring to the outlet from the pump, if there is a downstream blockage/valve closed the pump cant actually pump, it may be able to clear the little water from the strainer basket out but nowhere near enough volume to suck from the pool and prime/run. I would expect you...
  9. D

    New pool owner, can I do this?

    Have you tried disconnecting the 'out' from the pump? and seeing if you get any suction? Maybe your filter or something downstream is so clogged up there is no path out for the water If there is a blockage after the pump then if it cant blow it cant suck... You might get wet :)
  10. D

    Added Phosphate Remover to SWG

    How long do you 'normally' run it for if its 6-8 hours and you have run it for 24 there is your answer...
  11. D

    Hi & question re slamming pool

    The big blue 15L tubs of 'Pool chlorine' from Bunnings or elsewhere are 12.5% chlorine, last time I bought one it was approx $12 though you pay a deposit on the container and just swap out the empties for full ... Pool math suggests you need approx 4.4L of this to go from 0-24FC on your 23,500Lpool
  12. D

    Do I need a variable speed pump?

    One thing to be mindful of is will the low speed on your 2 speed keep your SW chlorinator full, I have a VS speed pump which would happily run at 800rpm but anything less than about 1200rpm the SWG cell housing wont stay full of water causing the low flow error and the whole thing shuts off...
  13. D

    New to pools downunder please help

    fgin, one thing to consider, your pool FC will behave differently with/without the cover on. I am currently heating mine(heat pump) so have the cover on when not in use, once dec/jan gets here i'll probably leave it off until march, it'll pretty much stay at 26 by itself. SWG Level/Pump run...
  14. D

    Copper sulphate based Algacide -

    I found something from NQ-100 Complete Test Kit - NQ Pool Test Kits which seems to be like the TF100 the folks like here, they were low on stock though the other day. Without knowing your cya you can't really be on top of your FC, now you have algae its more important than ever to have good...
  15. D

    Copper sulphate based Algacide -

    Farsonic, I have the P600's baby brother the p320 in my 40k Litre pool, I did some calculations that 800rpm would theoretically have been more than enough to keep my pool clean, however 800 rpm isn't enough to keep the SWG cell full and not trip out with a low flow error. The P600 should be...
  16. D

    Hi from Australia

    Have a look at these and see if the contents will do the job? NQ-100 Complete Test Kit - NQ Pool Test Kits
  17. D

    Fatty/Greasy above the waterline

    Edwin, My first spa I had for about 5 years before discovering this site, I had similar slime problems above the waterline, since finding this site and understanding chlorine little more, I now just use 12.5% pool chlorine, dispensed into a graduated ketchup/PVC bottle, After using the Spa...
  18. D

    Fatty/Greasy above the waterline

    Looks like skin oils/residue to me, needs more chlorine.... Do you maintain a residual FC between uses?
  19. D

    Swimmer's ear -- treatment and prevention

    I used to do a fair bit of Scuba Diving and suffered on and off with this, I mix up a solution of 50/50 Rubbing Alcohol (IPA) and Hydrogen Peroxide in one of those pipette bottle things, drop in a few drops in each ear after getting out. Its one of those things that easier to prevent than cure...
  20. D

    Used Spa

    I don't have that CYA test so not sure but presumably it means you have NO CYA in there, if you are soaking in 8.8ppm Chlorine that's not going to be nice on your skin, might be some explanation to your rash. I have 30 ppm CYA in my tub I squirt 100ml of 12.5% Chlorine in after using which gives...
  21. D

    Chlorine levels when adding salt to pool

    Probably the same reason FC is 'supposed' to be 1-2 just the industry standard without the knowledge we get here :) I'm sure if you asked a Pool Store employee they would tell you the pool would spontaneously combust adding salt with an FC of 3.1 ! I used the Sun Ray from Bunnings & Big W, some...
  22. D

    Chlorine levels when adding salt to pool

    I have just added 40 Kgs after the rains, my Fc is up around 8ppm I didn't give it a moments thought, we had approx 350mm over the 2 days salt dropped from 4000 to 3000. I have just added a heater and a cover which is messing with my SWG and FC levels which I had just got on top of. I'm guessing...
  23. D

    Any tricks or suggestions for pumping out the last few inches of green pool water?

    Do you have a main drain or as we call them hydrostatic relief valve down there you can take out/open/take the cover off which you can then shove the pump into? it should be lower then and drain the last bit out?
  24. D

    Hot Tub High Temp

    http://www.artesianspas.com/Mkt-Downloads/Line-Drawings-Specs-Owners-Manuals/Island/Owners%20Manuals/IslandElite_OwnersManual.pdf Assuming your keypad looks like this... P28, some kind of parental/child lock might be on...
  25. D

    Persistent water quality problems [VIDEO]

    I got a new spa back end of last year, until recently ( and with my previous spa) I had been dumping in all manner of lotions and potions thinking it was something that just had to be done, having just built a pool and seen the success of the TFP Method there, I have dispensed with my spas...
  26. D

    Moved and have no idea about new system

    Looking at your pictures, your pump is 'sucking' from 5 different places, 3 unlabelled, 1 x main drain and 1 x cleaner, you need to get more suction from your cleaner line, with those jandy valves the 'flap' opposite the handle sits across any pipe you want closed. No idea what the 3 unlabelled...
  27. D

    Understanding ampacity ratings

    Phew that was heavy reading, I'll have a go at most things but if you need to know that, for me its sparky territory... During my build we put in a new 63A supply to the pool area from the house main board. Sparky temporarily rigged up the 32A supply for my Spa but the cabinet had nowhere to go...
  28. D

    Wasn't expecting a pool?!

    One of the designs we looked at last year incorporated some grass inside the 'fenced pool area' Honestly I couldn't imagine anything worse, lugging the mower in to cut 2 Sq Meters of grass, spreading grass clippings everywhere, but the bigger problem I envisaged was dirty/sludgy feet in and out...
  29. D

    Suggestions for an outdoor shower

    I have one of those solar showers, we had no way to run a hot feed easily to put a normal shower in, works perfectly(on a sunny day).
  30. D

    Heat Pump Install

    Shed has a Polycarbonate roof under the wood, This is what I was afraid of, looks like it needs to be outside then, I guess it can be part cladded to try to conceal it a little Thanks, Simon