Search results

  1. fletchusmc

    Understanding Aquarite SWG function

    Firstly I want to confess my ignorance with regard to the detail functioning of the generic SWG and the specific Hayward Aquarite systems. I have an original Goldline Aquarite XL SWG paired with a Jandy Aqualink RS4 with an All button remote. I am currently running a Hayward W3T-Cell-15...
  2. fletchusmc

    StaRite SR400 error code 05

    Well, here is the final disposition. The control circuit board was bad. Received another new one today, installed it and everything works fine now. I appreciate the comments and suggestions, a little knowledge and experience go a long way. Keep up the great work. Tony
  3. fletchusmc

    StaRite SR400 error code 05

    Or perhaps the board is bad? It is a revision 8 board, I think that is the latest version. I have verified it is set up for the sensor and not the switch. I tend to also suspect the board because I can't display the exhaust temp when everyone else does. However I also suspect the board runs...
  4. fletchusmc

    StaRite SR400 error code 05

    Thanks for the interest Paul. A little background: A lightning strike fried the circuit board, transformer and ICM. The heater sat dormant for about a year until I found time to work on it. Replaced the 3 electrical parts, the heater fired up but immediately began thumping and rattling...
  5. fletchusmc

    StaRite SR400 error code 05

    haha, creepage, started out with one part which led to another and then another. I am only out $1125 so far, and with the exception of the blower and gas valve I have a new heater. Just wish it worked. But seriously, every step seemed like it should have been the fix. If the heater...
  6. fletchusmc

    StaRite SR400 error code 05

    Have an SR400 converted to propane. Approx. 15 years old. Just finished replacing the: Tube sheet, igniter, insulation, thermal regulator, new manifold with new sensors and bypass valve, Ignition control module, main circuit board and finally the stack flue sensor. Circuit board is rev. 8 and...