Search results

  1. S

    Raypak RP2100 digtal pool heater

    ok thanks for your time.
  2. S

    Raypak RP2100 digtal pool heater

    The out port to check gas pressure i have no pressure on my wc gauge.The inside of heater clean it's inside a house, And I clean and check heater yearly
  3. S

    Raypak RP2100 digtal pool heater

    The valve is Raypak replacement part# 003900F (Honeywell VR8304)
  4. S

    Raypak RP2100 digtal pool heater

    I smell no gas. The out port to check gas pressure i have no pressure on my wc gauge. been running just start have issues.
  5. S

    Raypak RP2100 digtal pool heater

    It is natural gas. the gas valve clicks after the pilot lights. Gas pressure coming to unit is 7" wc.
  6. S

    Raypak RP2100 digtal pool heater

    Yes the gas valve clicks and i have 24 volts.
  7. S

    Raypak RP2100 digtal pool heater

    I'm working on a raypak Rp2100 digtal unit with a pilot.it's sparks pilot comes on you here the gas valve open but has no gas coming out of the test tap. i have already replaced the gas valve still the same thing, but when the flame shows on the front panel you only see one of the flames flashing.
  8. S

    RayPak 2100 heater does not ignite.

    I'm working on a raypak Rp2100 digtal unit with a pilot.it's sparks pilot comes on you here the gas valve open but has no gas coming out of the test tap. i have already replaced the gas valve still the same thing, but when the flame shows on the front panel you only see one of the flames flashing.