Search results

  1. M

    Intex 2650 16 inch Sand Filter/SWG loses power?

    I took the switch out of another Intex pump, actually. However it turned out not to be a problem with the rocker switch as the unit would still brown-out and shut-down for no apparent reason. A new SWG electrode made no difference either (once I got my hands on a fresh one finally!). I finally...
  2. M

    Intex 2650gph SWG Sandfilter pool pump loud when starting...

    Yeah but it does the same loud sound when starting on the bench... ie. no water in it, no load. - Michael
  3. M

    Intex 2650gph SWG Sandfilter pool pump loud when starting...

    Ok, so why is this pump so blasted loud when it 1st starts up now? It's almost a growl until it gets up to speed, then it's quiet and has excellent flow. The bearings are smooth, I checked no problems there. The impeller is clear, everything is tight. It's just very loud for the 1st 2 seconds or...
  4. M

    Intex pump disassembly

    Yeah, that was supposed to be plugged in as you found out yourself! LOL! In order to take the unit apart, you have to unplug it as a 1st step (the housing cannot be removed from the pump motor while that's connected)... someone must have taken it apart prior to you acquiring the unit, and...
  5. M

    Intex 2650 16 inch Sand Filter/SWG loses power?

    I called Intex, could barely hear them there's something wrong with the phone system there (though the operator said he could hear me... bad connection maybe? IDK.). They don't have any of these titanium electrodes and don't show any coming to North America right now, so still stuck here...
  6. Saltwater Electrode.jpg

    Saltwater Electrode.jpg

  7. M

    Intex 2650 16 inch Sand Filter/SWG loses power?

    Tried that already... nada. Thanks though, great minds think alike! :cool: - Michael
  8. M

    Intex 2650 16 inch Sand Filter/SWG loses power?

    Ok, update... it's the titanium chlorine generator electrode SWG cell that's the problem. The system runs just fine now (with the main switch replaced) in Filter/Pump only mode, it's only when the SWG portion of the system attempts to power up that the system browns-out and reboots. A close...
  9. M

    Intex 2650 16 inch Sand Filter/SWG loses power?

    Ok I decided to sign up for membership to this site as I'm having a really odd problem with my SWG unit... it seems to be losing power and resetting itself (almost as if the household power were blinking off and on, which it isn't!). I found it apparently off when it should have still been on...