Search results

  1. M

    Intex Pump Modification

    Thanks for your help
  2. M

    Intex Pump Modification

    Well I tried the groove but it has to be recessed more for the hose to slip over but I was afraid to go deeper because I may cut through the pipe...anyway I replaced the PVC pipe with a new 1" threaded male to 1" slip...the 1" threaded goes to the pump...and I put the hose over the 1" pipe added...
  3. M

    Intex Pump Modification

    Charlie... Yes I have a dremel tool although it might be hard to get the groove straight...I have the o-ring from an old filter casing...I find PVC 3/4 inch fittings and PVC 1 inch pipe to be the right dimension for putting hose ends on...the tube idea is good one too...It got exhausting trying...
  4. M

    Intex Pump Modification

    heres the new setup it works good I have one problem tho the hose is leaking on the end where it goes to the pump...the hose end slips over a 3/4 coupling and it fits snug so I can't figure out why its leaking...infact the 3/4 coupling is a perfect fit its the same diameter as the filter outlet...
  5. leak.jpg

    leak.jpg

  6. pump.jpg

    pump.jpg

  7. M

    Intex Pump Modification

    So far so good I'll post some photos of completed mod
  8. M

    Intex Pump Modification

    I hope so...we'll see
  9. M

    Intex Pump Modification

    anybody have any comments
  10. M

    Intex Pump Modification

    heres a drawing
  11. drawing.jpg

    drawing.jpg

  12. M

    Intex Pump Modification

    The more I think about it I should set it up on the other side instead of what I have...
  13. M

    Intex Pump Modification

    Yes I have Unicell filter and it works good! As it goes right now the pump is pulling (sucking) the water thru the filter (see photo) and it goes from from the outside to inside and back to pool I've thought it would work better to PUSH the water through... but the setup would have the pump...
  14. M

    Intex Pump Modification

    I've taken the old pump out already...removed it from bottom plate with a saw and broke it out in fact once I cut the epoxy the pump came loose...then I epoxied where the pump was and then put a plastic plate over it so its nice and neat...then I put the plate back on the bottom of filter... I...
  15. M

    Intex Pump Modification

    It makes a little noise I put a valve in between pump and filter cartridge...it didn't make a difference though I noticed when I shut off pump and open the air release it lets out air and then the water starts flowing It's strange when I open air release with pump running water does not flow out...
  16. M

    Intex Pump Modification

    Thank you for welcoming me! Yes that's a problem I think it cavitated one time is there a way to make it a pressure through it would work better rather than suction through
  17. M

    Intex Pump Modification

    Hello everyone I would like to share a photo of modification to Intex Pump...the pump died so I hooked up a EcoPlus Submersible Pump 1056 (pump can be used inline and it pumps 1083 GPH)...what do you think By the way I have a 10 ft Intex Pool
  18. photo.JPG