  1. B

    jandy iaqualink

    1) I currently have linked and can control mine from at least 5 separate wireless devices. Not sure but I don't think there is a limit. I have it loaded as an App on the devices. Only limit is you can only control from one device at a time. 2) Wired controllers are typically wired directly to...
  2. B

    New deck heaving

    Thinking outside the box... is the waterline still even? Could the pool be sinking, causing pressure to heave the deck?
  3. B

    Pergola addition

    Correct! You can transfer the angle of slope easily by just holding the post plumb in the location you intend to attach, lay a flat piece of wood next to the post following the slope, then just scribe a line on the post. That will give you the angle and just adjust the cut to the height you...
  4. B

    Pergola addition

    Hi Mia... Just for the future, those are the wrong post bases for your application. PB should have set bases that have a U below grade with heavy straps extending above grade for the post to be through bolted. Those bases would have been set in cement before your patio was poured. You can still...
  5. B

    suntouch, pump and SWG wiring questions

    Cant tell from your pictures, but are you using conduit from the power center to the equipment? If so, you shouldn't use romex in the conduit. Romex is intended for exposed use and can overheat if run through conduit.