Search results

  1. P

    DIY Solar Heater - Flow Issues

    No, I have not put the solar cover on --I plan to get a reel at some point, which will make it more practical. We've had several nights this week that have dropped to 40ish, which obviously diminishes the value I'm getting during the daytime. That being said, is there a guideline (or typical...
  2. P

    DIY Solar Heater - Flow Issues

    I ended up adding a 3/4Hp Booster Pump (Hayward 6060). Without the booster pump, I was at ~21gpm return from panels, and 3 psi on the roof. With the booster pump, I'm at ~40gpm return and 14 psi on the roof. Eventually I plan to modify plumbing layout based on the above recommendations, but...
  3. P

    DIY Solar Heater - Flow Issues

    Thanks for the feedback guys. Re-plumbing the return lines to the opposite side of the roof is something that I'll add to my punchlist. Do you think this has potential to resolve the low flow through the collectors without need for a booster pump? Otherwise, my thought is that if it's going...
  4. P

    DIY Solar Heater - Flow Issues

    Yes, going into this project I was completely aware that DIY coil panels are less efficient than the commercial panels. I had run across the coil concept on several solar websites, in which they appeared to have decent results –however, they didn’t express similar flow issues that I’m dealing...
  5. Split Supply-Returns.jpg

    Split Supply-Returns.jpg

  6. Opposite Supply-Returns.jpg

    Opposite Supply-Returns.jpg

  7. P

    DIY Solar Heater - Flow Issues

    Thanks for the input! At this point, I'm trying to decide if I'd receive much benefit in re-plumbing without first buying a larger pump or a booster pump. Re-plumbing would be more time/effort, but definitely a cheaper solution than a new pump. But, if I'm going to need a new pump regardless...
  8. Supply-Return Piping.jpg

    Supply-Return Piping.jpg

  9. P

    DIY Solar Heater - Flow Issues

    Hello All! I’ve recently finished installation of solar panels for my pool, in which I’m trying to troubleshoot my flowrate/performance. This was a DIY project that I started last fall, knowing that it will undoubtedly be less efficient than a commercial system (no going back now!). My...
  10. Equip Pad.jpg

    Equip Pad.jpg

  11. Piping.jpg

    Piping.jpg

  12. Panels.jpg

    Panels.jpg

  13. P

    My D.E. Filter Wants to Explode