  1. J

    reccomendation to balance salt water pool

    I have a SWG pool; 20 K gallons, in ground, gunite. Where I keep it: FC - 1 to 5 ppm pH - 7.4 to 7.6, no higher than 7.8 CH - 175 - 400 ppm TA - 80 - 120 ppm TAc - 50 - 80 ppm CYA - 70 - 80 ppm Salt - 3000 - 3500 ppm My pool is in it's third season, it has never been out of LSI balance.
  2. J

    CYA Test Results

    A pool store tested my SWG, pool water, CYA level on 7/6/13: 73 ppm. After 3 - 5 inches of rain and three pump outs of excess water, I had the CYA level tested again on 7/27/13: 68 ppm. I used Taylor test kit K-2005 and received a reading, repeated three times, of 45 ppm. Given an error...
  3. J

    Which Test Results to Believe?

    I use Taylor's K-2005 and TFTestkit TF-100 to test my pool water daily/weekly. I do the weekly test on Saturdays. Through June and so far this month my test results have been very consistent. After yesterday's, weekly test I took a sample to the pool store for a "professional" water test...
  4. J

    How To Reach Breakpoint Chlorination With CYA at 75 ppm

    Wanted to report on the results of this topic: Sunday night I began the shocking process following the advice I received at this site, i.e. I added (very quickly) 3.9 gal. of liquid bleach, 12.5%, which is approx. 24 ppm for my SWG pool. At that time, CYA was 60 ppm. My purpose was to remove...
  5. J

    How To Reach Breakpoint Chlorination With CYA at 75 ppm

    Thank you for the quick reply :-) When you say shock level do you mean the suggested FC level from the pool calculator (20 ppm) or do you mean the FC level from the Chlorine/CYA Chart (28 ppm)? Thanks
  6. J

    How To Reach Breakpoint Chlorination With CYA at 75 ppm

    I want to remove 0.5 ppm of CC. The formula, CC x 10 = ppm of FC to add to reach breakpoint, is clear enough. However, because of the presence of 75 ppm of CYA in a 20K, SWG, IG pool, should more than CC x 10 = ppm of FC be added to overcome the CYA? And, if so, should that additional FC be...