Search results

  1. N

    Jandy AquaLink and Heat pump

    Thanks - yes, this is what I am expecting to happen...but I never get the 'JANDY REMOTE ONLINE PUSH MENU TO DISABLE' message. The manual makes no mention of whether what the explicit 'Remote' setting should be when attempting 485 bus communication. Reading between the lines I guess that means...
  2. N

    Jandy AquaLink and Heat pump

    Hi PoolGate - thanks for the reply. That was my initial assumption - but the wording in the aqualink installation threw me. You say 'set your HP for remote control' - on the Heat Pump there are three options for remote control 'OFF', 'HI-LO-COM' and 'REMOTE TSTAT'. Do you know which it is...
  3. N

    Jandy AquaLink and Heat pump

    I have a PDA-Ps6 and a Jandy Pro JE Heat pump - and am having difficulty with the rs485 based control of it. The heat pump installation manual suggests that for aqualink connectivity you can choose *either* 2-wire Remote TSTAT or the 4-wire bus, whereas the aqualink instructions seem to...
  4. N

    Leak detective work

    Latest update. Gave in and called a leak detection company (who were outstanding) After a good while he located the leak - under the new deck. He said it sounded like a decent size break based on the speed at which the air escaped under the pressure test. Today we jacked the concrete at his...
  5. N

    Leak detective work

    Right...but I think it rules out the idea of a blockage. Need to ponder whether I think that is a good or a bad thing! Sent from my iPhone using Tapatalk
  6. N

    Leak detective work

    Quick update - I managed to seal the reverse flow...and all it managed to do was start filling the pool via the main drain. At a relatively good rate...with no noticeable leaks. I found a pump, so am going to drain it a bit...fix the remaining return to keep the chem in line and keep...
  7. N

    Leak detective work

    Slight complication at the moment is that I need to drain the pool below the level of the jets to repair that pipe. Guess I better go get a sump pump! Sent from my iPhone using Tapatalk
  8. N

    Leak detective work

    Good question - it was under some pressure...but certainly not sealed. At the various points of the pipe I have exposed I can hear a water trickle every now and then. I also saw the occasional small air bubble coming out of the main drain in this reverse flow configuration. A clog buster...
  9. N

    Leak detective work

    I have the line exposed pretty much from the pad through the damaged area and don't see any issues (or it being tied in elsewhere). I also tried filling all the trenches with water - but no difference. The screen is in place on the drain. Quite the conundrum - I guess part of the question is...
  10. N

    Leak detective work

    I'm having some fun and games with a new (to us) pool and its plumbing.... Some context: in ground pool, overflow spa. One main drain, two skimmers - diverter at pad. We had some work done to replace some of the pool deck, and in doing so some of the pipe work got damaged - primarily the spa &...
  11. N

    Help identify equipment

    Update: Yes it's a check valve. And I was wrong about it being the main drain suction line - it is actually the spa return. (Both 1.5"). Glad I noticed or I would have the new valve in the wrong way! That aside - the spa return actually has a check valve type nozzle on the jet. Wondering if...
  12. N

    Help identify equipment

    It does look a bit like a clean out trap - but it's definitely on the main drain suction line. I'm going to clean it off today and see what's what.... Sent from my iPhone using Tapatalk
  13. N

    Help identify equipment

    Ok - spring loaded so it doesn't require the water pressure? Thanks! Sent from my iPhone using Tapatalk
  14. N

    Help identify equipment

    I think they need a decent column of water to keep the seal...so the pad might not work. Maybe put it in an irrigation box? Sent from my iPhone using Tapatalk
  15. N

    Help identify equipment

    Interesting - makes sense as the equipment is a few feet above the pool. Never seen one like that - but the pool is pretty old. I should probably put a new one in then?! Sent from my iPhone using Tapatalk
  16. N

    Help identify equipment

    We are having some work done to replace some of the pool deck - and in doing so some of the plumbing got damaged. In cutting out some of the pipes I found this on the main drain pipe (along with some very convoluted joints). It was buried about 2ft below ground. Can anyone help me identify...
  17. N

    Question about spa jets with a blower

    Mark, Thanks for the feedback. The filter is clean - but doesn't appear to have made any difference. I will be able to get to clear the jet lines on the weekend. Is there a recommended way to do it? I am also interested to understand where the tee would (should?!) be pulling air from if the...
  18. N

    Question about spa jets with a blower

    Mark Thanks - it is pretty clear to me that there is no expected Venturi effect with these jets. That said, the way they behave with just water being ejected is actually quite nice. Once they are working ok, the jets are very powerful. The basket and impeller are clear. What is interesting to...
  19. N

    Question about spa jets with a blower

    Thanks Mark The filter gets backwashed fairly regularly - last time was about two weeks ago. It is running at about 18-20 psi now. The need to run the blower initially to get the spa jets to flow has always been a problem (for us, at least - we have been here 3 years). With the blower on...
  20. PPuDrMN_small.jpg

    PPuDrMN_small.jpg

  21. N

    Question about spa jets with a blower

    Mark - thanks for your reply, and the link to the posting instructions Some more info: * The pool is approximately 25k gallons. The spa is attached and 'waterfalls' into the pool when in pool mode * It uses a DE filter (although we are using ZeoFiber) - a Purex Triton * Both pool and spa...
  22. N

    Question about spa jets with a blower

    Hi TFP I have a problem with my spa jets - and am doing everything I can to try and research the problem before posting a generic 'help' request. I am sure my problem is already answered in one of the threads here, I just need to piece together a few more details. These are the two threads I...