Search results

  1. B

    Jandy 1400 not working

    The 11 volts from the power cord is strange
  2. B

    Jandy 1400 not working

    11 volts at the cord. Also has a 121 code. It’s a 3 port. How do I test this thing? Continuity through the cell? Seems like 11 volts is low. Suggestions before I spend a grand?
  3. B

    pool skimmer material

    what are the skimmer boxes made of?I found a crack in the side of mine and I was thinking some pvc or abs glue and pipe shavings would be a better fix than epoxy.Any thoughts?
  4. B

    Main drain/hydrostatic relief leak

    Can I loop or tie the 2 lines inside the skimmer together and allow the pool to circulate with the water below the skimmer box? Or will this cause a air gap and cause the pump to lose prime.
  5. B

    Main drain/hydrostatic relief leak

    Do the hydrostatic valves leak or deteriorate enough to leak in an 8 year old salt pool? I am losing about1" a day.skimmers are tested fixed. Plumbing was tested lights tested. I cant find any cracks.Might be a coincidence but I over filled my pool before vacation.over the top. Now I have a huge...
  6. B

    Fixing a leaky skimmer.

    Skimmers are not leaking. I left the pool pump off and let it leak below the skimmers. I am losing about 3/8 every 8 hours.everything was fine until I overfilled the pool and it spilled over the deck.Could I have a failing hydrostatic?8 year old pebble tech salt pool.I will fill and run for 8...
  7. B

    Fixing a leaky skimmer.

    What is the best product to seal up the leak between the plastic skimmer and the tile?I have used 2 part epoxy as a bandaid but it never holds up.it is a salt pool.I plan on lowering the water and removing the stone on top and the tile inside for better access.I've been waiting for a product...
  8. B

    general fault chlorine generator 25500?

    ok, I put new sensor in and its all good. the new sensor has a board that plugs into the board but it is too tall and will not fit in the panel. Now what?
  9. B

    general fault chlorine generator 25500?

    Been running the salt a little high for about 2 months now. 3900ppm.As the water went down I noticed the level went to 4200 then the general fault.I added water then noticed a general fault and it said 25500ppm.Would this be caused by the salt level or is my 7 year old sensor bad?It is a jandy...
  10. B

    skimmer leak fixes?

    looking at a product called ardex wa.I think it is an epoxy grout adhesive used in underwater salt applications.
  11. B

    skimmer leak fixes?

    where the mouth meets the tile.it's not cracked.its the joint where the plastic and concrete meet.
  12. B

    skimmer leak fixes?

    Hello,The name is Ryan the problem is a leaking skimmer.Here I have a leak where the skimmer meets the gunite pool.What is the best way of fixing it? I plan on removing the stone above the mouth for better access.The 2 part epoxy seems to be a temporary fix.there has to be a better fix.thanks in...