Search results

  1. S

    A river ran thru my pool

    With all the rain in Texas, the ground is saturated and last night we got a very hard rain which cause a river of run off to flow into my pool and cause a mess. The pool was crystal clear, and not it looks like a dirty pond with zero visibility. Should i keep the pump off for a few days and...
  2. S

    New 2 Speed pump only runs low speed for exactly 30 minutes

    I have replaced my broken single speed pump motor with a two speed motor and added a 2 speed relay to my Aqualink RS6 controller. I configure the pump runtime to be 12 hours, and the low speed to start after two hours and to run for 10 hours. The pump starts and runs for the first two hours as...
  3. S

    Jandy 2-speed pump relay install

    I am in the process of replacing a non-working 2hp single speed Jandy Stealth pump motor, with a new 2-speed motor. I have a Jandy Aqualink RS6 controller, and I see in the manual that the new 2-speed relay gets connected to the AUX-2 plug that my blower is currently connected to, but other...
  4. S

    Replacing pressure gauge on a Jandy DEL60 Pool Filter

    My current pressure gauge works fine, but it is almost impossible to read because the plastic lens is so cloudy so I would like to replace it. Can i replace just the gauge, or do i need to purchase the complete air gauge release assembly. I see that the gauge can be purchased separately, but...
  5. S

    2 speed replacment motor recommendation

    My single speed 2hp filter pump just died and I was just about to order a replacement motor, but I'm thinking about replacing it with a 2 speed. I have a Jandy JMPU2.0 that uses an Emerson EB796 56J Frame single speed 1.5hp motor. Does anyone have a recomendation for a good 2 speed replacment...
  6. S

    "Air Temperature Sensor Open" message on Aqualink RS panel

    On my Aqualink RS control panel it says "Air Temperature Open". Since there aren't any other issues with the system, I thought I might have a bad temp sensor, so I broke out the meter and it tested good at 7.47 Ohms. I have also switched positions of the Air and water temp sensor and the error...
  7. S

    Water supply line in my skimmer

    I have an in-ground plaster pool that has two skimmers. The other day I noticed a white pvc line that entered one of the skimmers from the top and protrudes about two inches straight down into the tunnel just behind the weir. I then found a pvc ball valve in an in-ground round irrigation valve...