Search results

  1. M

    Hayward SP714A vs SP714T

    Good ideas. I may just replace the whole thing. Thanks!
  2. M

    Hayward SP714A vs SP714T

    Thanks! That makes sense. Is there a reason (pro or con) to just get the body? It looks like this would fix my problem since the leak is on the body. Although a complete replacement might be just as well since I don't know how old it is and will have it all apart anyway.
  3. M

    Hayward SP714A vs SP714T

    I opened the pool yesterday with hardly any issues. When I started the pump, water started leaking out of a crack near the pressure gauge in the multiport. It isn't leaking too badly so it's not a big deal. I plan to try epoxy to stop the leak first but I was searching for a new replacement...
  4. M

    Tired of Hauling Bleach - Let's fix the SWG

    I'll add my .02 regarding the Taylor salt test. Whether you get results that match the SWG or results that are different, the SWG will only work when it's satisfied with the salt level. It won't care what another salt test result is. If the SWG is happy, then I would be happy. My only...
  5. M

    First Timer!! Have AIR BUBBLES out of returns?? Pressure Test Kits Available?

    Since you have a SWG, they produce bubbles at the returns when they operate. It's supposed to happen but can look like an air leak. Turn off the SWG and see if the bubbles disappear to rule out the SWG.
  6. M

    Is this cell bad?

    Thanks for the quick reply. I'll let the water warm up and I bet that will solve the problem.
  7. M

    Is this cell bad?

    I opened the pool last weekend (Yay!) and the water was nice and clear (YAY!) but my Aquarite SWG said the salt level was at 1800 ppm and wouldn't produce chlorine. I had emptied out some water when I closed and added some when I opened so it was plausible that the salt level was accurate. My...
  8. M

    Pool losing water after closing!

    If the gizmo is the leak source and they left some pipe disconnected at the pad the water could be running into the skimmer line to the pad and draining out at the pad. The outlet would have to be lower than the skimmer though. If that's it, it's an easy fix. I hope that's all it is. It's...
  9. M

    Air locking the main drain this year!

    Maybe it would help if I posted a photo of my valve. I assume it's not repairable but since I don't know what kind it is, that's a blind assumption. There's no obvious damage......it just won't hold an air lock. Here's a photo...
  10. M

    Air locking the main drain this year!

    What's a guy gotta do to buy a valve on-line? I've looked high and low for a 2-1/2 inch ball valve that has a union also and can't find any on any of the pool parts sites including amazon. Plenty of 1", 1-1/2", 2" and 3" but no 2-1/2". I measured and am fairly confident 2-1/2" is what I need...
  11. M

    Air locking the main drain this year!

    Thanks for the input. I realized the valves also need a union included and I don't think Jandy offers one. It appears Praher does so I may go that way. I did use an expanding plug with a shrader valve in the pump inlet last fall. It had to cover the main drain and both skimmers. When I...
  12. M

    Air locking the main drain this year!

    Last year, while trying to air lock my main drain I think I damaged my existing ball valve. I would blow air into the main drain line and could see bubbles coming from the main drain. I closed the valve and when I opened it to see if the air lock held, water was on the other side. It didn't...
  13. M

    Advice on tarp please

    Some companies offer longer anchors for pavers. They are about a foot long if I remember correctly and are meant to be driven into the ground. If you choose to do that, I'd increase the size of the cover. Otherwise, the straps between the cover and the anchor may not be long enough.
  14. M

    I need to find out where my underground plumbing is in order to put in new fence post

    I assume you have PVC lines. If you have copper, a metal detector would help. Also, I'm not sure if I actually saw this or I'm making it up but what about calling a plumber to come put a special snake in the lines from the pool side that transmits a signal that can be received above...
  15. M

    I'm Thinking of Making a Bypass to Replace my SWG in the Winter.

    When I replaced a cell last year I kept the dead one for just this reason. I take the new one in for the winter to keep it out of the elements and put the dead one in to keep critters out. I've been meaning to cut the cord (literally) on the dead one so I know which is which.
  16. M

    Caretaker 99 blockage

    That stinks. There's something blocking the water somewhere but it sounds like you've covered everything. I'd be interested to hear what the repairman says.
  17. M

    salt flow regulator repair

    What make and model of SWG do you have? Assuming it's not a proprietary brand you could probably cut the wires and re-insert them in a new generic jack from a local store. Depending on which one you have, I bet others that model can send pictures of the wire order to help.
  18. M

    I think my return line is leaking

    I get a little sand on the step too. I wondered if I had a cracked lateral in my sand filter (I see you have a DE filter though...). It filters just fine so I doubt it with such a small amount of sand escaping. Then I wondered if it's just dirt I notice more readily on my white stairs compares...
  19. M

    Caretaker 99 blockage

    My first thought would have been a dirty screen or filter but you have that covered. You might take the water valve apart and force air or water through each pipe to narrow down the problem.
  20. M

    HELP!! Pool leaking water 6 inches in 2 hrs!!

    Good plan. Let us know how that affects the leak.
  21. M

    HELP!! Pool leaking water 6 inches in 2 hrs!!

    Something must be changing to let the water leak....it has to. An unintended siphon....is there a hose in the pool? The first thing to check is the last thing you did before the problem started. I would start troubleshooting to rule things out. If it's leaking with the pump running you can...
  22. M

    Pump won't prime and shuts off after 30 seconds

    My first three thoughts: 1)Your impeller may be stuck so the pump won't move water. With the pump turned OFF, reach in the pump basket towards the pump and see if you can turn the impeller by hand and check for leaves, twigs, etc 2)You may have a clogged line between the skimmer/main drain...
  23. M

    Broken pipe under slab! How to fix???

    Great news! That sounds like a win to me! If you don't see a drop in the water level after 24 hours, I'd chalk it up to a crazy winter and move on.
  24. M

    Broken pipe under slab! How to fix???

    If it were me, I'd troubleshoot some more to confirm that's where the leak is before I broke up the concrete. Can you isolate that run (plug the end in the wall) and fill it with water and see if it disappears? It would suck to break up the concrete to find out that's not the problem.
  25. M

    Do you know how to troubleshoot low pressure at the 9-port Paramount water valves?

    If this were my problem I would detach the "spaceship"/water valve and turn on the pump and watch the water come through the pipes to where the spaceship was. If there's zero pressure coming in to the spaceship, water will trickle in and you have a clogged pipe. If the problem is the...
  26. M

    check salt and check cell lights flashing on Aqua Rite

    No dice with the diagnostic button reset? There are several posts for fixing circuit boards on this site. It's a $10 cost compared to a several hundred dollar cost. I resoldered my circuit board having never done it before and saved myself about $400. Very much worth reading up on if you ask...
  27. M

    Cloudy pool

    My guess is that the "stabilizer setting is 100%" refers to the SWG. I could be wrong though..
  28. M

    check salt and check cell lights flashing on Aqua Rite

    The clean cell light comes on when there is build up on the plates AND every three months as a reminder to check the cell. You should be able to hold down the diagnostic button to clear the check cell light. If it doesn't go out, you may have a bigger problem. What is your salt level? If...
  29. M

    Do you know how to troubleshoot low pressure at the 9-port Paramount water valves?

    My first thoughts are 1) a clog restricting the flow to the water valve or 2) a pump problem that's causing it to slow down/restrict flow. Does your system have a strainer just above the water valve? It catches dirt before it gets to the water valve. If it's full, that would cause your...
  30. M

    Who has installed their own heat pump?