Search results

  1. B

    Normal gauge pressure but low flow

    For the last several days (and probably longer) I've noticed the water flow into my pool has dropped noticeably: very little surface disturbance near sidewall nozzles, less pressure from the floor jets. The pressure gauge on the filter tank shows its normal 28-30 psi. I've cleaned the two...
  2. B

    Motor Bearings or Pump Seal??

    I have a 1.5 HP Pentair Whisper Flo inground pool pump (0 177451 - 03). I hear a scratchy/screechy noise coming from the pump/motor assembly. The noise has come and gone for a few years now. I'd like to avoid a catastrophic failure in the height of pool season. I plan to replace the seal or...
  3. B

    Where's My Chlorine Going?? And How Do I Stop It?

    Pool details (I can’t edit my signature for some reason and the data in the signature area is incorrect): 22.5 k gallon free form plaster/pebble pool, 1.5 HP Pentair WhisperFlo single speed pump, Pentair FNS DE filter, Aquacal Aerotemp 155 heat pump, 3” tabs or bleach used depending on CYA...
  4. B

    CYA Went to Zero Over the Winter????

    Just before closing our pool last fall I had the cyanuric acid level tested at a pool supply place--they said it was 77 ppm. We just opened the pool and I had the water tested at the same pool place. They say the CYA level is now at zero ppm. I had them test it again one day later and they...
  5. B

    Stabilizer Level Increases Significantly While Adding Only a Small Amount of CYA????

    Eight year old 22,500 gallon pebble finish gunite pool in Massachusetts with DE filter and heat pump. On 6/12/2016 the stabilizer level was 51 ppm. On 8/15/2016 it was 70 ppm. And on 8/29/2016 it measured 84 ppm. The first and last tests were performed by the same pool place; the middle...
  6. B

    Cracked Heat Exchanger in Heat Pump

    Today I opened our inground pool. As soon as I powered up the circulator pump copious amounts of water flowed out from the Aquacal Model 155 heat pump. I removed a number of panels from the unit and discovered there was a vertical crack (maybe 1/20th of an inch wide and 2 inches long) in the...
  7. B

    Pool Heat Pump Runs but Doesn't Heat

    We have an AeroTemp model 155 heat pump for our swimming pool. It's about 5 years old and doesn't get used all that much. The other day I noticed the heat pump wasn't running at all. I reset the circuit breakers which had tripped. Now the heat pump powers up (panel lights up, fan runs) but does...
  8. B

    Why Does my pH Rise So Quickly?

    Background information: 22,500 gallon gunnite/plaster pool with pebble finish, 5 years old, DE filter, Whisper Flow pump, Nature2 Pro G mineral sanitizer, in-floor cleaning system, no water features, light bather load, sunshine on pool from 9 AM to sunset, located in northeastern Massachusetts...
  9. B

    Concrete Pool Deck Sealing

    We have a five year old in-ground pool with a stamped concrete pool deck. The pool builder applied a sealant to the deck that looks to be completely gone. I'm wondering if I need to re-seal. Would not re-sealing it significantly shorten the life of the deck? I know the sealant provides a...
  10. B

    Chlorine Usage Calculations

    I’m considering switching from the trichlor hockey pucks to liquid chlorine. I wanted to get a feel for how much bleach or pool store liquid chlorine I’d need. So I did a chlorine usage calculation for the trichlor pucks. I purchased the pucks on Aug. 5, 2010. I assumed I started using those...
  11. B

    Constantly Adding Balance Chemicals--Is This Normal?

    Background: 22,500 gallon fresh water inground gunite pool with pebble/plaster finish, Pentair WhisperFlo pump with 1.5 HP motor, Pentair vertical grid FNSP60 D. E. filter, Nature2 G sanitizer, Pentair 320 inline chlorine feeder, and AquaCal AeroTemp heat pump all located 30 miles north of...