Search results

  1. delaneybob

    High water Temp on RJ-60

    Understood about the warranty. For me its the easy button to just swap the cell but more expensive. Plus I have had to do quite a few AA treatments for staining due to a leak that was fixed and although the cell was off during AA, you never know.
  2. delaneybob

    High water Temp on RJ-60

    Thanks I contacted support and they recommended the flow switch and wire jumper and leaving the current cell in. The issue is within the cell as that is where the temp sensor is. The quick fix is to put in a new flow sensor with a temp sensor as well and jumper the controller so it reads the...
  3. delaneybob

    High water Temp on RJ-60

    Hi, got 167F on the reading after i noticed it blinking this morning. Recovering Chlorine with bleach and weighed the flow switch change vs a new cell. I opt'd for both and will determine which way I will go this weekend. I have 3 years on the Rj-60 cell and debating if its worth swapping the...
  4. delaneybob

    AA Treatment - weird results

    Here's the official word from ProTeam When lifting stains or reversing other pool water issues relating to metal problems, the pH must be raised and the chlorine lowered as directed. Maintenance doses, the pool should be maintained between the “normal” daily ranges a pool should be kept at...
  5. delaneybob

    AA Treatment - weird results

    Great thanks- their instructions on their website doesn't delineate the free CL recommendation between initial and maintenance. Algae test passed last night FC=5.8ppm CC=0ppm Turning on the SWG and hoping my leaning to more Borax for pH control saves me my relatively high Acid adds going...
  6. delaneybob

    AA Treatment - weird results

    Thanks for the info. I am doing the overnight run to test for algae prior to turning on SWG. Using 25ml FAS test FC=6.2ppm CC=0 ppm
  7. delaneybob

    AA Treatment - weird results

    I used 32oz of 12% Peroxide for 4.5ppm Chlorine. By your calcs that should have been 20 oz of 12% peroxide vs 32 oz I used. However Peroxide itself is inherently unstable and decomposes to water "eventually"- FDA has the half life of 90% Peroxide at a little over a week in typical sunlight...
  8. delaneybob

    AA Treatment - weird results

    Thanks. Jst realize there is no calculator here for peroxide other than here and I did it in 2 increments and appeared to calculate correctly for my pool "27% hydrogen peroxide at a reasonable price of $17 per gallon. It would only take 115 fluid ounces (around 3-1/2 quarts so somewhat less...
  9. delaneybob

    AA Treatment - weird results

    Yes thank you. I tried the cu-lator last year to try to help that and it appeared to work as most of my staining was from the previous AA and having to SLAM over long period. The ultra high Cl combined with PH that kept going up rapidly cause some metals to re precipitate during the SLAM. I...
  10. delaneybob

    AA Treatment - weird results

    Thanks for the peroxide tip and will use more AA next time. Sorry about not mentioning the sequestrant, I added 32 oz Pro team metal magic on initial run after 12 hours of AA- same for second. This morning I removed cartridge and cleaned it. Once pool stabilizes, I will replace the...
  11. delaneybob

    AA Treatment - weird results

    Ok here are the results I put 2 gallons on bleach in (over 6 hours) and brought Free Cl to 5ppm FAS using the 10ml method. I know that normally about 20 oz of 7.5% bleach raises my pool 1ppm. This morning Free Cl =5ppm :) Ph=7, TA=40, CYA=80. I overshot CYA more than I would like but used...
  12. delaneybob

    AA Treatment - weird results

    So alot better on the AA - I am suspecting the peroxide to be the culprit on the first go around. Pool is at PH=7 and pool temp is at 60F. I looked at this thread and will start to bring Cl back up despite the AA working slower than last year. Last year was in Spring or Fall and the Polaris...
  13. delaneybob

    AA Treatment - weird results

    Pool stains slowly lifting. It must be the pool temp (60-65F). I will let it run but I do not have algae forming (used alot of algeacide on first attempt)- I will start pool recovery tomorrow evening/Friday morning
  14. delaneybob

    AA Treatment - weird results

    I just put in 2 lbs of AA (I ordered the one mas965 said Amazon.com as the one I ordered got back ordered) Cl=0 and PH =7.1 only difference is I did not use Peroxide to lower Cl. Cl was slowly coming down (I assume due to bad batch of AA that had some kick to it)- running for 24 hours and...
  15. delaneybob

    AA Treatment - weird results

    Thanks- much appreciated but I already ordered the new AA :)
  16. delaneybob

    AA Treatment - weird results

    Ok thanks- I will regroup and try a different vendor AA. On the iron stains- yes I did tablet test on steps and have that stain remover on pole thing for spot treatment as well. I just ordered this As it will get here today. Will repost after AA treatment but things missing from this forums...
  17. delaneybob

    AA Treatment - weird results

    Amazon- same place as before. In fact the first 1lb was from last years (left over)
  18. delaneybob

    AA Treatment - weird results

    PH is 7.2 and Chlorine is 4 ppm FAS. I should have to add like 10-13 gallons of bleach to get rid of the AA and get chorine to hold. Its almost as if I never added the 2 lbs of AA Pool temp is 65F that is also a difference than last year when I did it when it was in Spring- pool temp likely...
  19. delaneybob

    AA Treatment - weird results

    Hi, I am doing my second annual stain removal with AA and got weird result. Only difference this year is I used Hydrogen peroxide to lower Chlorine. I used 32oz of 12% H2O2 to lower 4.5ppm Cl to zero (2 x 16 oz treatments before starting) SWG is off At start Cl=0 and PH was 7.0. Added...
  20. delaneybob

    How to maintain Chlorine range with an SWG (Sunny and Cloudy days)

    I go the new display in and am running it per previous post and took the SWG to 25% since 50% previous for about 1/2 the time maintained the right level Step 1 8am-6pm Start RPM 1300 end RPM 700- SWG should be on during day and cut off at 6pm Step 2 6pm-4am Start RPM 700rpm end RPM 2100- SWG...
  21. delaneybob

    How to maintain Chlorine range with an SWG (Sunny and Cloudy days)

    Thanks looks like the display has gone bad so will get that replaced before changing
  22. delaneybob

    How to maintain Chlorine range with an SWG (Sunny and Cloudy days)

    I was wrong- I have 3 settings- see attached picture. Each Step has a begin and end rpm and the adjacent time rpm needs to match Aux port power to SWG timer (this is part of the VSP) starts at 12:00am and can be set to apply power for X hours over YY RPM So Maybe do Auxport on for 14 hours...
  23. Picture1.jpg

    Picture1.jpg

  24. delaneybob

    How to maintain Chlorine range with an SWG (Sunny and Cloudy days)

    I get it and thanks- aware of the brutal FL sun in the days to come. Prior to the VSP I ran the single speed for 8 hours at night (3450 RPM though) same with the SWG at 20% and overshot the Chlorine over time during the summer and that was with the leak and lower CYA. The controller on my VSP...
  25. delaneybob

    How to maintain Chlorine range with an SWG (Sunny and Cloudy days)

    Also the reason for running at night is well girlfriends cats- they don't like the Polaris spray :-) so prefer to run Polaris at night- that's why the SWG is on at night. I guess I could run the pump lower rpm but above the float switch cut off but then that make the Polaris less efficient and...
  26. delaneybob

    How to maintain Chlorine range with an SWG (Sunny and Cloudy days)

    Whopps I thought the sidecar was sufficient so I added that and more to the signature On the speed question- it was right around 1000 rpm when I first go tit installed ( I tested it) On the watts question no clue- Power =V*I*PF , All I have are the pump curves for flow rates
  27. delaneybob

    How to maintain Chlorine range with an SWG (Sunny and Cloudy days)

    Hi Jim- thanks and understood. I will see how it goes. I am open to changing the way I am running and will talk to discount pool tomorrow on min GPM for the cell. The float swithc to me is a backup and not to be the main mechanism to stop the SWG One thing of note: When I called Discount...
  28. delaneybob

    How to maintain Chlorine range with an SWG (Sunny and Cloudy days)

    Thanks the issue I am trying to avoid is the restaining of the pool which was a combination of things but with my leak fixed, its less about iron water coming into the pool and more about keeping PH under 7.5. to prevent any precipitation of iron PH for me seemed to go up faster the higher the...
  29. delaneybob

    How to maintain Chlorine range with an SWG (Sunny and Cloudy days)

    Hi All, Running my SWG at 50% for 6 hours in the overnight (this is being done via an aux port on my VSP)- I keep my pump running rest of time around 700rpm which is too low for the SWG but conserves electricity. I bought the 60,000 gallon Cell for my 8,800 gallon pool so i could replace the...
  30. delaneybob

    CYA effectiveness at different levels- is this chart bogus?

    Ok no worries thank you. And apologies for being myopic but with my leak fixed- I can finally really stabilize the pool :)