Search results

  1. PoolingInKC

    Pool & Spa Heat Command - Getting IntelliFlo to increase RPM when heater kicks on?

    I found this older thread (below) and while it sort of answers my question, it didn't answer it 100% and I want to pose this to the experts on here. I have a new IntelliFlo3 VSF and I have programmed it to change RPM's when the heater is on for either the Spa or the pool - or so I thought. The...
  2. PoolingInKC

    Old pump blew out - repair or replace question

    Hi All, My pool was installed in 2014 so the main pump is now 10 years old and it gave up the ghost when it was energized during reopening today. I have two options from my pool company to consider and thought, hey, TFP would be a good place to bounce this off of. I have the Pentair...
  3. PoolingInKC

    Resetting ScreenLogic Protocol Adapter (PA) - personal experience

    Realizing that these are older threads (below), I do have some information that I feel will be helpful should someone search the forum for issues with the ScreenLogic Protocol Adapter being picked up by the PC based ScreenLogic application. I had this issue crop up a while back when I had to...
  4. PoolingInKC

    Recent Issue with Pentair IC-60 Salt ppm readings (and resolution)

    So, about the first of July, I noted that the FC was dropping in the pool despite the SWG being set where it's always been set where it maintains 7-9 ppm FC. I checked the SWG settings and the Salt ppm was reading 2000. Well, I knew that the salt ppm was closer to 3,400 based on how I keep the...
  5. PoolingInKC

    General question on accuracy of drop tests vs other tests

    Starting out by saying that I have the full TF-100 test kit plus the K-1766 Sodium Chloride test kit and I use them religiously and have for 5 years. Recently my IC-60 stopped reading the salt content of the water correctly (shutting it down) and in the interim, trying to prove to the pool...
  6. PoolingInKC

    Wooooo Hooooo! Success..............

    I just wanted to pop in and say that going into last fall/winter I was fearing the closing of our pool. Why? All of our prior openings found nasty, murky, greenish brown water. Normal time to get cleared was 5 days and a lot of work. Last fall, I read the sticky on "How to close an above...
  7. PoolingInKC

    Checking in with first TF-100 test results

    Hi TFP Forum! As noted when I first joined, I did get a TF-100 kit and have run my first tests. FC 4 ............... (Pool Math Goal 3-10) CC .5 PH 7.6 .............(Pool Math Goal 7.5 to 7.8) TA 90 ............. (Pool Math Goal 60 - 80) CYA 70...
  8. PoolingInKC

    Intro: PoolingInKC

    Hi Forum! We live in Overland Park, KS and had our pool built in 2014. We upgraded our automation to a Pentair EasyTouch system with iPhone remote access this spring and are loving it. The only recurring issue I seem to have is water clouding up after heavy rains but normally that clears up...