Search results

  1. D

    High current draw - Hayward Super Pump

    Thats correct - when I had the 2607 impeller on, the motor was pulling about 14.5 amps. I did not let it run very long since it wasn't pulling enough water to fill the reservoir. I have actually put the 2610 impeller back on because the 2607 would not draw enough water to prime the pump. Huge...
  2. D

    High current draw - Hayward Super Pump

    Yes, when everything is put together the impeller spins freely. The breaker that was tripping is a 20A GFCI breaker. That is on the 220 circuit. I am now running the pump on a 110 circuit, a GFCI outlet. That circuit has never tripped. Therefore I have concluded that I have a problem in...
  3. D

    High current draw - Hayward Super Pump

    I did have the 2610 impeller. I swapped it out with the 2607. Result was that it would not prime , even with the reservoir nearly full at startup. I had no suction at the far slimmer basket. So it would not create enough flow. Additionally it only dropped the amperage on the motor to 14.5...
  4. D

    High current draw - Hayward Super Pump

    Thanks much! The total hp is 1.1. Hp is 1.1 and sf is 1.0. It may be a while till I can take it apart to get the impeller PN but I’ll do that for sure.
  5. D

    High current draw - Hayward Super Pump

    When i replaced the motor initially last year, I replaced it with the same total hp as the old motor that stopped working. I do not know what the pump model or impeller part number is. They are the same as when I bought the house - have not been changed. This morning, I swapped out my 110V...
  6. D

    High current draw - Hayward Super Pump

    Roger that. Will get that in place right away. This all makes sense. At 115 v the current draw will most likely come below the rated level - confirms that there is an issue in the wiring of my 220 circuit. I just have to isolate and fix that. Thanks to everyone - you have all been very...
  7. D

    High current draw - Hayward Super Pump

    Not sure the gage of wire but could only be 16 ga
  8. D

    High current draw - Hayward Super Pump

    Voltage at the outlet is 120 so I’m good there. The extension cord is 100 ft and is a 15amp rated cord so probably undersized for the amount of power the pump is drawing.
  9. D

    High current draw - Hayward Super Pump

    I can’t really check that now since I’m temporarily using an extension cord to power the pump - not going through a switch or timer
  10. D

    High current draw - Hayward Super Pump

    JamesW - I may have replied at the wrong place on the thread. Voltage is 107.
  11. D

    High current draw - Hayward Super Pump

    From what JamesW said that’s low. What would cause that? This is a brand new motor by the way.
  12. D

    High current draw - Hayward Super Pump

    I haven’t checked the voltage. Will do that.
  13. D

    High current draw - Hayward Super Pump

    James - thanks! So I believe there is a wire problem in the normal 220 circuit the pump is on. So now I have it running on 110 using an extension cord plugged into a GFCI protected outlet. The motor is correctly wired for 110 - moved the plug to the 110 spot and verified neutral and hot are on...
  14. D

    High current draw - Hayward Super Pump

    Basics - 28,000 gal in-ground pool. 1 HP motor rated at 6.6A at 220V and 13.6 A at 110V. Built in 1989. Owned house last 5 years. Problem - after I had the pool opened two weeks ago, everything ran fine. 2 days later had problem with circuit breaker blowing. I've isolated that problem to...
  15. D

    New to TFP and chemistry question

    So, I'm back. Still having issues - here is what I have done. I did drain about 1/3 of the water and replaced with fresh. Got the test kit. It was very helpful in that it did show me that I have 0.5 FC, not none, as I had thought. Starting point was CC - 3ppm, CYA is low - near 0. Water...
  16. D

    New to TFP and chemistry question

    Thanks. I'll get the test kit on order right away and start adding bleach until I get some FC to register on my strips.
  17. D

    New to TFP and chemistry question

    I forgot to mention that I did add 5 bags of shock and next day, still 0 free chlorine, but there was dead algae in bottom of pool. - - - Updated - - - Sorry - yes 7.0
  18. D

    New to TFP and chemistry question

    PH is 7.
  19. D

    New to TFP and chemistry question

    Hello from Southern Indiana (Louisville KY area). I'm new to the forum. If I've got this set up right, most of the info about my pool is in my signature. This is my 3rd season opening pool - my first pool. Replaced liner first season so its just a couple years old. Had no problems opening...