Search results

  1. T

    Nitro or Chem Geek - TA level?

    Hello, My error I got Chem Geek and Nitro reversed. See the screen print below with the TA recommendation in red. Note it is with a condition ..... using Bromine tabs. (which I use) chem geek Join DateMar 2007LocationSan Rafael, CA USAPosts12,082 Re: Low TA perfect PH in SpaWelcome to TFP...
  2. T

    Nitro or Chem Geek - TA level?

    Hello, My recent 320 gal hot tub refill of city water was: 46F, pH 8.0, TA 50 & CH 50 out of the tap. After balancing, the hot tub water is: 100F, 4ppm Br, pH 7.8, Borate 60-80, TA 50 & CH 150. The water looks and feels clean. I have no issues with foam or any kind of build up. Nitro...
  3. T

    Hot Tub fresh fill - City Water 50ppm & 7.8pH

    Hello MPurcell and Pooldv, Thank you for the replies. I have a Hydropool hot tub and the aeration jet is separate from the pressurized self cleaning filtration system. The aeration jet sends a steady stream of fine champagne like bubbles into the hot tub 24/7. If the optional ozonator is...
  4. T

    Hot Tub fresh fill - City Water 50ppm & 7.8pH

    Hi Pooldv, Thank you for the quick reply. Yes, I have been doing that but the TA drifts down the pH drifts up so I end up TA 40ppm and pH 7.8-8.0. It turns out there is an air injection system factory built into my hot tub. It runs 24 hours per day in tandem with the filtration system. The...
  5. T

    Hot Tub fresh fill - City Water 50ppm & 7.8pH

    Hello, I recently used Ahh-Some, flushed and refilled my hot tub. City water to start: TA 50ppm CA 50ppm pH 7.8 I build a bromide bank to 30ppm with liquid sodium bromide and use a floater with BCDMH pucks to sanitize. After one month: TA 50ppm B 30-50ppm - Gentle Spa (it is hard tell...
  6. T

    Pre Hot Tub Shower - Soap or No Soap?

    Hello, From the TFP forum I now maintain my hot tub as follows. Purge the hot tub: Ahh-Some Balance the water: 7.5 pH, 50ppm TA, 50ppm Borate & 130ppm CH Sanitize the water: 30ppm Sodiium Bromide and add floater set to 1/2 with 3 BCDMH pucks for 3-5ppm Bromine target. (the floater allows...
  7. T

    Sodium Bromide - How much chlorine to add daily?

    315 gal hot tub Tested with Taylor K-1004 test kit. pH 7.4 TA 60 ppm CH 150 ppm Borate 40 ppm (based on the Gentle Spa label recommended amount) Sodium Bromide 30ppm (based on the label's recommended amount) I added 2 oz sodium hypochlorite (10%) around 3:00pm. Evening test strips showed both...
  8. T

    TA increased from 60ppm to 100ppm?

    City tap water - pH 7.7, TA 50ppm, CH 50 ppm. After balancing - pH 7.5. TA 60ppm, CH 160ppm. I removed several pails of water and relaced with tap water to lower the CH below 150 ppm. Added Gentle Spa (4 oz per 150 gal) to get 40 ppm. Added (125ml per 1000L) sodium bromide to get 30 ppm...
  9. T

    Gentle Spa - Amount per Hot Tub Volume = ppm

    How much Gentle Spa to get 30 ppm? How much Gentle Spa to get 50 ppm? I was told by Proteam 4 oz by weight per 150 Gal = about 40ppm. It is easier to measure fuild amount when adjusting for another fluid amount such as gallons. Proteam also said you cannot overdose Gentle Spa. My TA is 70...
  10. T

    Sodium Bromide - Liquid or Powder?

    To establish a bromine bank in a hot tub, which is better sodium bromide in the liquid or powder form? Or does it matter as long as 30 ppm is reached? Thank you.
  11. T

    First Fill New Hot Tub

    Yes, I have read both the bromine and chlorine several times. I spoke with the Ahh-some CEO and he said a finger dab once a week would keep the plumbing clean. Hot Tub Serum makes a product called Total Cleanse that I suspect is a watered down version of their product similar to Ahh-some. The...
  12. T

    First Fill New Hot Tub

    I just want to check that I am using the Pool Math calculator corrrectly. New 315 US Gal hot tub. Sanitizing with Bromine to allow for not testing the water every day due to holidays and those extremely cold days when we don't venture outdoors. Usage will be two people, shower before each use...
  13. T

    Bromine - chlorine shock - bromates?

    I have decided to sanitize with bromine, BCDMH, because it allows me to miss a couple of days at a time when I am away from home or the temperatures drop below -25C. Since BCDMH contains chlorine to oxidize the bromine it seems logical to shock with pool grade sodium hypochlorite (filtered and...
  14. T

    Bromine - chlorine shock - bromates?

    Hi Chem Geek, Below is an excerpt from another site. I suspect your reply was in the context of a swimming pool. I do not know if the same discussion applies to a spa. I have hightlighted your comments in red below. My questions are for a spa. QUESTION 1: Will shocking a BCDMH, bromine...
  15. T

    Bromine + Borates -> Bromate?

    Will adding borates, borax or Gentle Spa to a hot tub sanitized with bromine in the form BCDMH, create Bromates in the water?
  16. T

    Sequestering Agent: Once or Weekly?

    Thank you for the reply. You just confirmed what I was thinking. Everytime I add something another problem emerges. Yes, I have read both discussions. Calcium: What is the ideal calcium target? 125 ppm? Again thank you.
  17. T

    Sequestering Agent: Once or Weekly?

    Excerpt from "How do I use Bromine in my spa?" Here is a step by step: 1) On each fill balance the water (adjust TA and pH. Add calcium if below 125 for acrylic spas or below 200 for plaster.) If you have metals in your water add a metal sequesterant. Calcium: Is the target 125 ppm? (APSP...
  18. T

    Bromine Use In a Spa

    Thank you for clarifying the lower TA levels for bromine. Borates were not included in the "How do I use Bromine in my spa?" thread. I was trying to understand/determine if adding Borates (boric acid or borax/MA or Gentle Spa) to a spa sanitized with bromine in the form BCMDH would help...
  19. T

    Bromine Use In a Spa

    This is a request for Molson or another senior user to update the "How do I use Bromine in my spa?" thread. Are the Dichlor/Bleach methods to balance the water applicable to bromine? Will a TA between 50/60 ppm (minimum set by the APSP) & 80 ppm offset with Borates (boric acid or borax/MA or...