Search results

  1. B

    OmniLogic board issue?

    Hi gang, I have an OmniLogic powering a T-15. I had a generic cell model in not too long ago and it started giving low salt warnings when the salt level was fine (tested with a kit). It was a number of years old, so I assumed it was going bad and bought a new cell - true Hayward this time. The...
  2. B

    Plumbing arrangement - Heater / SWG / Acid dispenser

    Hi all - I'm currently operating with a SWG and VS pump (no automation as of yet). I'm having a gas heater installed shortly and would like to also add an acid dispenser to complete my quest for pool maintenance laziness. I believe the arrangement should be filter -> heater -> SWG without the...
  3. B

    Newly remodeled plaster (Hydrazzo) - metals and sequest testing?

    Hi all - I just recently had the pool refinished with Hydrazzo (woo-hoo). I have a couple of questions on the metals issue and the sequest needs... 1. We put the initial startup dose of sequest agent in (Jack's Blue Stuff). The product lists a "maintenance dosage" that would result in about...
  4. B

    Dolphin Z5 not climbing walls (not new)

    Hi all, I have a Dolphin Z5 that's probably 2-3 years old. It recently seems to have lost some vacuuming power and is having trouble climbing the walls. Just to clarify - it has been able to climb the walls in the past, and I am not running in fast mode. I left the cleaner in the pool for an...
  5. B

    Reintroduction of pool cover AFTER slam

    Hi all, I've just finished a SLAM after a little algae outbreak. I had a solar cover on the pool when the algae attacked and I took it off and rolled it up onto a holder during the SLAM process. I'm just wondering at what point I should put the cover back on given that it could potentially...
  6. B

    CO2 dispenser with Hayward Sense and Dispense

    I couldn't find much of a mention of anyone using the CO2 option with a S&D system. I'm thinking about adding this in now that have the SWCG portion installed. Can anyone give me any feedback from using CO2 vs an acid dispenser? Just to head off the cannon fodder - I have no intention of using...
  7. B

    Help wiring relay for SWG control

    So I finally got my salt cell installed and decided to go with a current sensing relay to drive the power to it since I just put in a VS pump as well. Here is the relay that I purchased: Macromatic CAH05A1BC 0.5-5A, 240V, 0.5-50 Sec, Current Sensing Relay I'm hoping that someone can help me...
  8. B

    FC diving during the day after SLAM

    Hi all - I've been lurking in the shadows, consuming the wealth of information on here and I have something that I can't seem to find a similar situation of and decided to post. First off, as some background - I've been using the evil chlorine tabs, powdered shock and a multitude of different...
  9. B

    Robots and salt cells

    I'm looking at purchasing my first robot. I also plan to switch over to a SWG in the next few months as well. In reading some reviews on one of the Hayward models, it sounds like it has metal screws that could result in a corrosion problem with a salt cell system. Does anyone know: A. Is this a...