    Need new pool cover

    10 x 40 SGW, plain rectangular, vinyl liner pool, 13 years old. Existing cover is LoopLoc. Cover is on its last winter, seam joints are separating because the cords used to sew panels together are disintegrating. Panels themselves are in pretty good condition. Did not use UV resistant material...
  2. S

    Pool deck + ants

    10 x40 Vinyl liner pool, cement pavers set in sand bed. Lots of ants. Ants at pool edge drag up sand which ends up in pool lowering level of deck! For 13 years. Have tried killing ants without success. I am looking for a solution to solidify the sand so that the ants will be incapable of nesting...
  3. S

    Two Skimmers: unequal flow?

    Problem: 10 x 20 in-ground vinyl pool (SWG) / 2 skimmers, one at each narrow end / Skimmer most distant from pump/filter has the greatest pull - even with flow-control slide plate shut down to 35% and other skimmer flow-control slide plate completely open. History: The original installation, 10...
  4. S

    No Salt being used?

    15,000 gallon in ground pool, 10' x 40' x 4', 9 years old Initial installation of pool was not good. Had 2 lights. First light had leak from the beginning but was, reluctantly, fixed by installer. Had to add water from the beginning but more and more as time went on. Last fall, under...
  5. S

    Leak Detection

    10' x 40' x 4.5' deep vinyl lined pool. Loses, in full summer, 1" per day when the water is above the skimmers. When the water drops below the skimmer the loss is about 1/2" per day. I have read elsewhere that, on average, 1/2" loss per day is due to evaporation. So, it seems that there might be...
  6. S

    Hayward C48L2N134B1 1.5 Need front end bell of motor housing

    Started replacing bearings that were making lots of noise. Took motor apart and found heavy corrosion of the front motor bell casting which makes re-use of this part problematic (there is a rubber washer retained by a steel washer [rusted to almost nothing] which would have to be replaced). The...
  7. S

    SWG start up low mineral (Salt) reading?

    Closing pool in the fall means emptying the pool about 40% +/-. Topping up the pool means adding salt in the spring at start up time. I have a Mineral Springs MS-10 generator which does not give today's reading (default reading) of salt level. The generator will not go on if the salt level is...
  8. S

    Sand filter high pressure: backwash does nothing

    Tagelus TA 60D sand filter, 6 port valve, 5 years old, low load - 2 people, on/off pressure differential = 18 psi. Backwashing/rinse cycle makes little difference. I do not accurately remember last years reading, but this seems much higher and there is a marker ring on pressure gauge that says...