Recent content by zoocrew

  1. Z

    Autopilot DIG220 0V .5A from readings

    I'll take a look at that to see if it was reset somehow. Otherwise it seems like a failed power module. I think I'm done with autopilot. I'm sure this question is for another forum, but anyone have any suggestions for a reasonably priced salt system for a pool sized at approx 24K gallons?
  2. Z

    Autopilot DIG220 0V .5A from readings

    OK, here are the results. @ 45sec = 11V .6A, @ 1min30sec = 9V 6A, @2min = 18V 6A, 2min30sec = 20V 6.3A, 4min 28V 6.2A, 4min30sec 28V 6.2A. The whole time the salt level was either 270 or 2800ppm. Boost mode was on at 100% on level 2. The problem light was blinking "bad temp sensor". After...
  3. Z

    Autopilot DIG220 0V .5A from readings

    We did more investigation on the system today. We put a meter on the end of the cable going to the cell. It read 28V so we know at least there is power coming from the unit to the cell. We did not have a resistor to put on to test for amps. Would a bad tri sensor cause a malfunction of the...
  4. Z

    Autopilot DIG220 0V .5A from readings

    The problem was happening at the end of the summer while the water was still very warm (which caused my pool to turn into a swamp). I ended up draining and cleaning the pool since it was a mess. The cell is literally brand new because I broke the housing on the old one taking it apart to check...
  5. Z

    Autopilot DIG220 0V .5A from readings

    I have an autopilot DIG 220 with the SC-48 cell installed. I am getting the dreaded low amps - check cell reading. Salt level is 2800 ppm, but the same reading occurs when the salt is at 3500ppm. I have been fighting this problem for awhile. The numbers that show up are 0V .6A. The system...