Recent content by yoitsme

  1. Y

    Started SLAM but confused...HELP!

    What test kit are you using? If I recall correctly, DPD and OTO chlorine get bleached when the FC is very high. That's why this site recommends FAS-DPD for chlorine test.
  2. Y

    Current CH 600, Tap water CH 300, what to do?

    When using cal-hypo for every ppm of FC, you added at least 0.7ppm of CH. You could double check this using pool calculator. In regards to whether you added that much CH, assume you lose 2ppm of FC each day, then you have added about 84ppm (2*60*0.7) of CH within the 2 months.
  3. Y

    Downsizing my impeller

    Thanks for confirming my dilemma. Yes, that specific pump's model uses the same diffuser. Unfortunately, most of the pumps sold in my country are single speed and the distributor has to indent it if I want the 2 speed or variable speed model.
  4. Y

    No Drain Acid Wash

    Instead of brushing, why not try using pressure cleaner to fasten the process?
  5. Y

    Downsizing my impeller

    I apologise for bumping this thread. I am new here and have been a silent reader in the last couple of weeks. Topic split. Please ask questions in your own topic rather than hijacking someone else's existing topic. JasonLion First of all, I have dilemma in regards to this topic. I am also...