Recent content by willyk9

  1. willyk9

    No LED lights on for my Aquarite SWG t-15

    Look at some of my recent posts, they include part #'s, ect...
  2. willyk9

    No LED lights on for my Aquarite SWG t-15

    When you say display board, do you mean just the LCD screen or whole main board? If you are getting no red/green lights then most likely same issue I had, need a new thermistor.
  3. willyk9

    Hayward Aquarite Diagnostics Problems

    I have pretty much the same unit with version R1.45. What do your lights on the panel show when you power it up? Mine would flash the no flow red light and then no lights on the panel. Look up my posts, $8 part from DigiKey and find someone to replace it on or do it yourself.
  4. willyk9

    Should pool be uncovered when running SWG?

    Yup, run mine all the time with the cover on.
  5. willyk9

    Need help with Oval pool liner installation

    My pool is 12x24 but the side walls are not 100% straight so my width is almost twelve and a half feet. Still not issue with a 12x24 liner but the key to mine is the depth, I needed a 52" liner.
  6. willyk9

    Is heating an AGP practical?

    One week later and I am maintaining 88 degrees :cool:
  7. willyk9

    Need help with Oval pool liner installation

    Having replaced a 12x24 oval in the past myself, the liner looks a little small for that pool?
  8. willyk9

    Solar Cover Saddles/Holder

    Such a great site this is!! Using this old thread I made my own DIY saddles and they came out great! https://www.troublefreepool.com/threads/making-solar-cover-saddles-holders-for-intex-pool-today.123214/ With inflation since 2016 everything cost me approximately $50 Oh and.....pool was...
  9. IMG_2520.jpg

    IMG_2520.jpg

  10. IMG_2519.jpg

    IMG_2519.jpg

  11. willyk9

    Need advice on liner!

    I'm no expert, but that liner looks like it was bleached.
  12. willyk9

    Aqua Rite help

    Correct, my AQT T-5 Cell with version r1.45 does not have the ability to change the cell type at the LCD screen. i have a T-15 to use as a backup if needed, then I would need to jump the J4 if I want to use it.
  13. willyk9

    Is heating an AGP practical?

    So...12x24 fully above ground was 68 degrees at the beginning of June when I opened. One month with a solar cover on 24x7, running pump 12 hours from 5pm to 5am, I'm pleased to say we enjoyed our 84-85 degree water all holiday weekend.
  14. willyk9

    Little stick or root poking up through liner on bottom of pool. - formulating plan for when/if it ends up breaking through at some point.

    Had the same as you a few years ago. Once it breaks through the liner it will most likely eat away at the sand/dirt underneath and start building a divot in the bottom. I drained the pool dry, used some flex seal to fill the divot and seal the leak, cut a piece of foam in a nice circle to fill...
  15. willyk9

    Is heating an AGP practical?

    I'm 100% above ground.