Recent content by wantobpoolmaster

  1. W

    Aquapure Output cable (R0512500) trouble

    Just an update for future reference. I replaced part R0512300 (Control Board) for $150 and the Output Fault display is now off. The SWG is producing Chlorine....
  2. W

    Jandy Aquapure Ei - output fault?

    I have the same "Output Fault" issue on Jandy Aquapure EI 35. Can the Salt Cell cause that message or just an Electrical issue where I would need to replace part R0512100 or R0512300?
  3. W

    Aquapure Output cable (R0512500) trouble

    I spliced the blue wire and black wire that get attached to the cell. When I wrap the black wire on the black terminal, I get a "No Flow". When I attached the Blue wire to the Blue terminal, I get an "Output Fault". Has anyone else seen this before? Thanks
  4. W

    Aquapure Output cable (R0512500) trouble

    Will do....Thanks for letting me get that out!!!
  5. W

    Aquapure Output cable (R0512500) trouble

    Unfortunately, every site I have gone to (approximately 10) say its discontinued and out of stock. Three even took my order only to get an e-mail that the order is canceled as they can not get the part. Even called Jandy and they also said part has been discontinued... I was hoping maybe...
  6. W

    Aquapure Output cable (R0512500) trouble

    This is the part I need that Jandy is saying is now discontinued.
  7. 1558634496002.png

    1558634496002.png

  8. W

    Aquapure Output cable (R0512500) trouble

    I am looking for the output cable R0512500 that connects to the cell, not the outlet.
  9. W

    Aquapure Output cable (R0512500) trouble

    My output cable for my Aquapure EI SWG is having a problem connecting to the cell causing an Output Fault. The wires from the black input split apart. I tried to find a replacement part R0512500 but am finding that part has been discontinued. Is there a replacement part or do I have to fuse...
  10. W

    TF-100 reads total chlorine 0

    Yes I have a SWG...Do you think I should shock beacuse FC-0 or am I losing FC due to low CYA?
  11. W

    TF-100 reads total chlorine 0

    Is it possible for pool to look "crystal clear" and have total chlorine read zero? Pool looks great but.......I am waitng for conditioner to come to raise cya to 70... fc-0 tc-0 ph-7.5 ta-60 ch-330 cya-40
  12. W

    Trenchless Technology

    Thanks. Found the pipe, dug it up, put in new pipe and now no more leak. I am a happy man
  13. W

    Trenchless Technology

    I have been fighting a leak in my pool for a few weeks now. An underground pipe has been spouting water. Been reading about trenchless technology where no digging is necessary. Has anyone heard of this and are there any disadvantages?
  14. W

    Pool Leak

    Thanks. Can that have any affect on my pool leak??