Recent content by TimU

  1. T

    Replace SWG Cell with oversized element

    Good thinking :) I've just spoken to Zodiac support and was advised as follows: For Clearwater models C140 - C200, the main control boards and power supplies are identical, barring a replaceable low-cost shunt. However the C250 model requires a different main control board at a cost of ~AU$175...
  2. T

    Replace SWG Cell with oversized element

    Hi All, Hopefully a quick "yes/no/don't be stupid" question from a long time lurker, first-time poster 8-) Am I able to run an oversized cell in my Salt Water Chlorinator? My power/timer unit is a Clearwater (Zodiac) spec'd to run a C140 element and outputs 7VDC to the cell. Photo...