Recent content by Timfree

  1. T

    New O/B Las Vegas needs help lol

    Just pm you about one of the excavation sub that I've known of.
  2. T

    New O/B Las Vegas needs help lol

    Please check your TFP's Inbox. Thanks
  3. T

    New O/B Las Vegas needs help lol

    Hi Brandwylie, QuingGuy said that you (sorry if not you) were sent a PM to me , sorry , I checked and have not received your msg . Please resend it if you still want to say something to me . Thanks
  4. T

    New Owner Build pool/spa,Henderson,NV, any comments, suggestions, advices are welcome

    Pass final inspection , Southwest gas came in to replace with a new bigger gas meter ! However , the Pentair Heater 400K BTU (460736) did not turn on , No power at all, A 1.25A fuse was blown and replace another one by builder , and was blown again !. There is some kind of short circuitry...
  5. T

    New Owner Build pool/spa,Henderson,NV, any comments, suggestions, advices are welcome

    Sorry QingGuy , I checked my TFP's inbox and the msg from @brandwylie is not found. Please use my email address instead. Thanks.
  6. T

    New Owner Build pool/spa,Henderson,NV, any comments, suggestions, advices are welcome

    Filling days ! Start 2015/12/18 1:30PM to 2015/12/19 9:48AM. Same time , close it up ! for you to compare Blue Quartz Plaster in the air and under the water . I was told that after cleaning all the white powder out , let say for about a week, then the blue quartz color should be more blue ...
  7. T

    New Owner Build pool/spa,Henderson,NV, any comments, suggestions, advices are welcome

    Re: New Owner Build pool/spa,Henderson,NV, any comments, suggestions, advices are... SOUTHERN NEVADA AMENDMENTS TO THE 2012 INTERNATIONAL SWIMMING POOL AND SPA CODE 305.8.4 Option four. A pool motion device, laser or light beam activation alarm system permanently installed that...
  8. T

    New Owner Build pool/spa,Henderson,NV, any comments, suggestions, advices are welcome

    Thanks Casey, Kimkats and Bigcarbs for your inputs . It should be done by this week. I had a chance to talk with the inspector. He said that the bypass button in 10 second OFF is there for those who to open and then may be walk around the side yard then forget all about it ,in the meantime a...
  9. T

    New Owner Build pool/spa,Henderson,NV, any comments, suggestions, advices are welcome

    Just pass the 2nd inspection today : (1673 = Interior Safety Device and 1675 = Pre Plaster) . Plastering (Blue Quartz) will be next , probably tomorrow (Thursday) or next day (Friday).
  10. T

    New Owner Build pool/spa,Henderson,NV, any comments, suggestions, advices are welcome

    Watering ....more watering for at least 7 days in the row ! FYI : POST SHOOT: "Setting up for curing is the next step and of extreme importance. The concept is simple enough. You have to make sure the surface stays wet as the concrete cures to prevent the evaporation of mix water. The idea is...
  11. T

    Pool Pump cover?????

    when we are talking about dB , we usually have to define where is 0dB level ? surrounding noise at certain times, days ? where is the reference in term of sound ?
  12. T

    New Owner Build pool/spa,Henderson,NV, any comments, suggestions, advices are welcome

    Thanks Kim , My wife, she loves doing something like that. yeah , I took a chance to call inspector back for a re-inspection the same day ! couldn't believe he did that for us. Shotcrete today ! 6 guys get it done in 5 hours ...from 7:00AM to Noon.
  13. T

    New Owner Build pool/spa,Henderson,NV, any comments, suggestions, advices are welcome

    Wednesday (today) morning 9:00AM First Hiccup…. Pre Gunite Inspection (1665) is failed: 1/ #8 copper conforming to shell of pool connected at only 3 points to pool bond beam. 2/ No bond to porch column latch weep screed. Here is the code from Henderson city, NV: “ 6613 First Pool Excavation...
  14. T

    New Owner Build pool/spa,Henderson,NV, any comments, suggestions, advices are welcome

    Thanks all for following and given me some meaningful thoughts on this build. 1/they did an excavation detail (hand crafted) on Friday. 2/ 4 guys get: · Plumbing (Auto refill water line, water pressure=25 psi, by-pass equipment’s (connect IN/OUT water’s lines together)). ·...
  15. T

    New Owner Build pool/spa,Henderson,NV, any comments, suggestions, advices are welcome

    Plumbing is done (equipments are connected later) , water's pressure (bypass equipments) is always kept at 25psi ! steel rebar ,electrical are also done . Inspection #1 is next.