Recent content by SunFun

  1. S

    Taylor K-2006 Combined Clorine and CYA level questions for Intex Ultra Frame w/SWG

    thank you for that link to the shock table... This particular Intex SWG unit is a Sand Filter Pump / SWG / Copper single unit. You can have the Filter Pump on only (SWG disabled) or set the SWG from 1 to 12 hours and it will repeat process 24 hours later (sleeping in between). Since I...
  2. S

    Taylor K-2006 Combined Clorine and CYA level questions for Intex Ultra Frame w/SWG

    UPDATE: Last week I added an additional 8oz of Cyanuric Acid in a sock. Filter Pump running for 3-4 hours before test, SWG on (with pump also on) for an additional 3 hours before this. Water Temp: 72 CYA: 55 pH: 7.5 FC: 14.5ppm (using 10ml, 29 drops) CC: 0ppm TA: 100ppm (10 drops) It...
  3. S

    Taylor K-2006 Combined Clorine and CYA level questions for Intex Ultra Frame w/SWG

    thank you Ahh, I missed about needed to run the pump 30 minutes before each test (it worked out this time as the SWG shutdown for the day at 11AM and I started testing 45 minutes later. EDIT: Pump needs to be running for at least 30 minutes before the test per jblizzle's post below. So to...
  4. S

    Taylor K-2006 Combined Clorine and CYA level questions for Intex Ultra Frame w/SWG

    Update: Last two days, ran the SWG for only 3 hours per day in the morning (Intex recommends 4). There has been no activity in the Pool yet.. may get some today. CYA: 55-58 FC: 7ppm CC: 0ppm TA: 90ppm CH: 50ppm pH: Not Tested I took these tests about 45 minutes after the SWG ended it's...
  5. S

    Taylor K-2006 Combined Clorine and CYA level questions for Intex Ultra Frame w/SWG

    Update: Yesterday I added a total of 32 oz of Borax (two applications of 16oz, 45 minutes apart and testing after the first).. pH at 7.6 (was 7.2 after the 1st 16oz, 7.6 after 32oz), and again 7.6 testing today. Note: Just before adding the first 16oz of Borax, tested TA and appears to have...
  6. S

    Taylor K-2006 Combined Clorine and CYA level questions for Intex Ultra Frame w/SWG

    Since my TA is fine now (around 80ppm) and I'm just interested in raishing pH, should I still find and get some 31.45% Muriatic Acid to have on hand if I go the Borax option? From reading a few threads, it does seem to me that Borax (33oz) would be the better option as Washing Soda will also...
  7. S

    Taylor K-2006 Combined Clorine and CYA level questions for Intex Ultra Frame w/SWG

    Does Borax = 20 Mule Team Borax? That is what I'm confused about now
  8. S

    Taylor K-2006 Combined Clorine and CYA level questions for Intex Ultra Frame w/SWG

    I'm still a little confused, are you saying to add the same amount of 20 Mule Team Borax as I would add Sodium carbonate (Arm and Hammer's Washing Soda or Kem-Tek's pH Plus)?
  9. S

    Taylor K-2006 Combined Clorine and CYA level questions for Intex Ultra Frame w/SWG

    I just found out we have Arm and Hammer's Washing Soda that we use in the laundry as a booster.... this appears to be the same has Kem-Tek's ph Plus for a lower price... From reading on the forum, it appears 20 Mule Team Borax will raise pH without changing TA, my TA is good... It appears I...
  10. S

    Taylor K-2006 Combined Clorine and CYA level questions for Intex Ultra Frame w/SWG

    Are you posting about 20 Mule Team Borax? I noticed in the Pool Math for my data, it says to add 17ox for Soda Ash (I would use Kem-Tek pH Up) or 34oz of 20 Mule Team Borax I can get 5lbs of Kem-Tek ph Up for just over $7, it seems I need 2x the qty. of Borax.. what am I missing?
  11. S

    Taylor K-2006 Combined Clorine and CYA level questions for Intex Ultra Frame w/SWG

    Well, Walmart, Home Depot, Lowes (they stock Kem-Tek) and a couple pool / spa stores are around.. I don't really want more than 5lbs and don't want a bag, do like the plastic container storage... I can check to see what Walmart has in stock and open to what else would be recommended to raise...
  12. S

    Taylor K-2006 Combined Clorine and CYA level questions for Intex Ultra Frame w/SWG

    I went a head and did the Taylor K-2006 pH, TA and CH tests pH - was yellowish so I assumed low, did the Base Demand Test which required 9 drops (maybe a 10th) TA - 8 drops (step 4), 80ppm CH - 5-6 drops (step 4), 50-60ppm (maybe more purplish at 5 drops, the 6th drop was definitely blue (same...
  13. S

    Taylor K-2006 Combined Clorine and CYA level questions for Intex Ultra Frame w/SWG

    Thanks guys.. I'll recheck in a couple days, then add more CYA if necessary (which I assume will be needed). I'll check pH later today instead of waiting. I also noted in my OP that our city water is chlorinated, not fluoridated.
  14. S

    Taylor K-2006 Combined Clorine and CYA level questions for Intex Ultra Frame w/SWG

    Hi, My setup in my Sig. Just setup the pool up last week, been about 6 days since I added 120lbs salt and 4-5 days since I added just under 1.2lbs of Cyanuric Acid per Intex 1% CYA recommendations for start (my water level is a couple inches lower). SWG/Pump is running 4 hours per day in...