Recent content by stoopstn

  1. S

    Trouble with Aquarite not generating, new cell

    Thanks. What would be a reasonable current reading while generating? I will pick up the test kit.
  2. S

    Trouble with Aquarite not generating, new cell

    Good call. Checked the thermistor this morning and had fallen off. Must have done a great solder job.....lol. All is working. Voltage now reads 22 and current of 8 while generating. Thanks again!
  3. S

    Trouble with Aquarite not generating, new cell

    3900 90F 0.0 0.0 60P -0.00 AL-0 r1.32 (looks like an r?)
  4. S

    Trouble with Aquarite not generating, new cell

    Moved into our place a couple years ago and have always used chlorine despite the pool having a salt system. Added the recommended salt up to 3200ppm and replaced the Cell (picked up a T-15 which is what it had). Turned it on and it wouldn't generate. The board was reading low voltage and no...