Recent content by simpro

  1. S

    Jandy LX 250. AGS error

    All re-re-installed and......... Nothing!!! Someone suggested Ign. Module?! $340?! Sent from my iPhone using Tapatalk
  2. S

    Jandy LX 250. AGS error

    Ok. Rewired ignitor. All cleaned up. Ready for reinstall when...... Wait for it..... I tapped the ignitor against the table saw in my way to reinstalling it!!!! Waiting on a new ignitor now $80.00 oopsy Sent from my iPhone using Tapatalk
  3. S

    Jandy LX 250. AGS error

    Hi. I looked deeper. I pulled the burner tray and WOW what a mess of black powder! Carbon?? Anyways I visually checked the igniter and then foolishly touched it (to see if it was solid) and ouch....shock! Weird-should only have been warm not energized. I look closed and found the wire shorted...
  4. S

    Jandy LX 250. AGS error

    Thx for the reply. I had it apart down to but not including the burner tubes. We've had a bout of real wet weather?!?! I will inspect for spiders...I have to check the fusible link but also thought maybe ignito r yet it read 80 ohms or so. Funny thatv'it just stopped running'!? Sent from my...
  5. S

    Jandy LX 250. AGS error

    Hello from Ontario Canada. I have a Jandy LX250. It try's to fire up but stops before heating and flashes "Service AGS". The furnace has been running for about a month with no problems. The only thing that I can think of that has been different is that we have had an ark fall of rain. I have...