Recent content by Shblack

  1. S

    Loosing prime

    Our pool pump is gradually loosing prime over time. The equipment: Pool is a 14x28’ in-ground pool with two suction lines feeding the pump, one from the skimmer, one from the bottom drain. The suction lines each have their own valve and come together about 24” before the pump. All plumbing is 1...
  2. S

    Booster pump having trouble starting

    Have a Polarus cleaner with a pentair LA01N booster pump, date on pump is 12/11/2015, pump is wired for 120V. Lately the pump has either been slow starting, or won’t start, just hums. With power off, I can reach between the motor & pump and turn the shaft, it seems “sticky”. Yesterday it...
  3. 7A89AB46-2EC0-45AA-86C6-12AEB05ED45B.jpeg

    7A89AB46-2EC0-45AA-86C6-12AEB05ED45B.jpeg

  4. S

    Booster pump doesn’t boost

    Yes, several times. Note that circulation pump is wired for 240V, booster wired for 120V. Clock stopped holding time during power outages shortly after warranty expired. Not impressed with Pentair at this point.
  5. S

    Polaris Booster pump

    Sounds like bearings have failed. I have seen kits for sale, though I had trouble getting the impeller off on our pump.
  6. S

    Booster pump doesn’t boost

    Wired for 120V, setup ran fine last year. Controlled by flipping a breaker, turned on and off several times. Water flows through the pump normally when circulation pump is on, no increase in pressure from cleaner port when booster turned on, no flow from cleaner port when booster only is run...
  7. S

    Booster pump doesn’t boost

    Opened pool yesterday, first issue is booster pump runs, but no pressure boost. Water comes out of cleaner port when circulation pump is running, but no increase due to booster pump being on. Opened pump, impeller looks good, spins when powered, passage ways in impeller clear, however pump is...
  8. S

    Booster pump doesn’t boost

    Have a Pentair LA01N booster pump, installed around 2016. Was running fine when we put the pool to bed last September, just opened pool, pool cleaner won’t run. Have moderate flow through the cleaner due to the circulation pump, but no boost. Can hear booster pump running, but quiet, opened...
  9. S

    Clock on Pentair Intelliflow

    Thanks, Tom. Probably a diode between the supply and capacitor that isolates the capacitor when power goes down. Either the capacitor has failed, or the current drain on the micro-controller has gone up. Pentair probably chose this approach to avoid the hassles of making a moisture tight...
  10. S

    Clock on Pentair Intelliflow

    Thanks for the feedback, will check on the O-ring. Looks like the thread on the clock not keeping time died out with no resolution. Anyone know of a schematic for the drive floating around, or a source that rebuilds the drive?
  11. S

    Clock on Pentair Intelliflow

    Installed a Pentair Intelliflow VS pump on our pool in Sept 2017, seemed to work great. Winterized the pool, ended up not opening the pool in 2018 due to health issues. Pool is open now, two issues: - Clock on pump controller will not remember time when we have a power outage, and we have power...
  12. S

    Pentair 227t shutting off and on, very hot, impeller spins freely.

    When we moved into our home the pumps had been sitting for a couple of years and the bearings had frozen up. Turn them on, they would hum, get hot, trip the breaker. Opened the pump up, spun the impeller by hand to break it free, pump ran ok for a year after that
  13. S

    Pump motor failed

    For the last couple weeks our pump motor would hum, then start slowly. This AM it would not start at all, just hummed, then started smoking. The motor is an A. O. Smith 3/4 Hp, 1.27 service factor unit operating off of 230V. Unit is probably 12 years old, was here when we bought the place. Pool...
  14. S

    Valve help needed

    Called Hayward pool products, got a really annoying recording that repeated every 30 seconds and stated that they were experiencing high call volume and that I should fill out the on line form for quick service. I ended up hanging up the phone, it been nearly 2 days and no response to my Email...
  15. S

    Valve help needed

    Thanks! I saw that site, all the valves I could find were a union on one end, glue on the other.